66
HUNTER-PRO 896 Installation Guide
Output type
What triggers the PCB output?
Not In Use
-
Not In Use
-
Remote Control
Activating an output by remote call
Not Used
-
Station ACK
ACK received from the MS*.
* This output type is used as indication that a report sent to the MS has been received.
When an alarm from a zone programmed to trigger the “Station ACK” output type
occurs, the PCB output programmed to be triggered by this output type “waits” for the
system to receive ACK. As the ACK is received the output is tripped for 10 seconds (and
can switch on bulb etc.).
5.8.3 Output
Partitions
Set the outputs partitions (see drawing in section
5.8), i.e. define which partitions are
enabled to activate which output.
5.8.4
Polarity & Activating in Disarm
Set the polarity of the output and whether it will be activated when the system is
disarmed (see drawing in section
5.8).
Par. Name
Marking “+” means…
P
Polarity
<+=Pos.
’+’ The output is disconnected in alarm
‘-‘ The output is switched to negative in alarm (GND)
D
Active in
Disarm
‘+’ The output is activated when the system is disarmed
‘-‘ The output is activated when the system is armed
5.8.5
‘Ext. Siren’ and ‘Int. Siren’ Outputs
These 2 PCB outputs distinct, due to the following reasons:
1. They’re both high current outputs.
2. They can trigger any speaker siren.
3. Ext. Siren output can be triggered only when Int. Siren output is. In other words,
activating sirens in HUNTER-PRO 896 can be done in one of three ways: Both
internal and External, internal only, no siren.
Note
: It is advisable not to associate only ‘External Siren’ and ‘Internal Siren’ to these
two outputs (this is the default programming).
You can, however, associate the external and internal output types to any other PCB
output, but then the sirens must be DC sirens (i.e. contain a built-in oscillator).