24
HUNTER-PRO 896 Installation Guide
I/O-WN Control
Panel
1 -V
-
2 +V
+
3 OUT
IN
+
-
+
HUNTER
-P
RO
8
96
zone
s
T AM PER
I/O -W
3
4
1-V 2+V
BU S
OU
T
IN
KEYPAD
Figure 12 - Connecting I/O-WN
Note
: For further information regarding I/O-WN, refer its guide
3.3.3.1 I/O-WN
LEDs
The I/O-WN has 5 LEDs, described in the following table:
Status
Description
LED
ON:
I/O-WN operating and connected to voltage
BLINK:
I/O-WN voltage fault
OFF:
Fault in I/O-WN device/connection to
voltage
I/O-WN processor
operation and
connection to
voltage
RUN
(Green)
BLINK:
Connection OK
ON:
Communication failure
OFF:
Short in communication wiring
I/O-WN
connection to
control panel
DATA
(Red)
BLINK ONCE:
Transmission from wireless device
received by I/O-WN
OFF:
No transmission received from
wireless device
Receiving
transmissions
RX
(Red)
BLINK ONCE:
Wireless device identified
OFF:
Wireless device not identified (no
reception from wireless device)
Identifying I/O-
WN's additional
wireless devices
VALID
(Green)
OFF:
No failures
ONE LONG BLINK
: I/O-WN did not receive a valid
frame from HUNTER-PRO 32
TWO LONG BLINKS:
I/O-WN did not receive ACK
from HUNTER-PRO 32
THREE LONG BLINKS
: I/O-WN is not programmed
FOUR LONG BLINKS
: General/Fatal error. For one
minute no communication from I/O-WN.
Communication
failures between
I/O-WN and
HUNTER-PRO 32
control panel
FAIL