HUNTER-PRO 896 Installation Guide
31
3.12
TRV/TRU-100: Long Range Radio Transmitters
3.12.1 Mounting
Guidelines
Following these guidelines will minimize RF interference:
Do not mount the Panel close to a metal wall or ceiling
Make sure you leave enough space for the antenna between the metal box and the
ceiling
Install the antenna at a distance from the Control Panel’s wiring
Mount the antenna after you complete all other installations
Make sure the antenna is not folded and is vertical
Close the HUNTER-PRO 32 metal box when performing transmission tests
3.12.2
Connecting the Transmitter
Note
: The TRV/TRU-100 can transmit in 2 frequencies
1.
Mount the HUNTER-PRO 896 metal box on the wall
2.
Screw the transmitter to the system box. Make sure the screws are tightened;
else, the transmitter’s range can be reduced.
3.
Connect the antenna to the transmitter. Make sure the antenna is straight.
4.
Make sure the 5-pin cable is connected to the transmitter’s Molex (named: “To
the system” on the transmitter’s sticker.)
5.
Connect the other end of the 5-pin cable to the male Molex, placed on the
Control Panel’s upper left side (named “Transmitter” on the Control Panel.)
To use the second frequency only:
1. Follow the pervious 1 to 5 instructions, and then:
2. Connect the 2-pin cable to the transmitter’s F2 Molex (named F2 on the transmitter’s
sticker.)
3. Connect the other end of the 2-pin cable to the control panel depends on the
desired transmitter operation:
To constantly work with the second frequency:
Connect it to (-) output on the Control Panel.
To work with 2 frequencies according to event type:
1. Connect it to one of the system’s outputs, such as ALARM or ON/OFF to one of the
PGM outputs: AL/ON/OFF/RELAY.
2. Program these outputs in “Outputs” menu (see section
5.8). The related parameters
need to be programmed in “Communication Configuration” menu (see section 5.4).