HUNTER-PRO 896 Installation Guide
67
5.8.6 Expanders’
Outputs
5.8.6.1 OUT-1000
7
ENTR
ENTR
BACK
ENTR
Output Configur.
ENTER/NEXT/END
OUT-1000 Outputs
ENTER/NEXT/END
Output 1
X3
Output 1
Fire
ENTR
Part. For OUT 1
++++++++++++++++
PD
-+
1
ENTR
Expander
Expander’s output No.
Output’s output type
Output’s partitions
Output’s polarity
Output’s No.
Set OUT-1000 (8 outputs expansion card) outputs. Besides the expander output
number screen, all other screens match the outputs configuration screens.
5.8.6.2 I/O-R
Configure I/O-R 32 outputs. I/O-R is programmed the same as OUT-1000.
5.8.6.3 I/O-8N
Configure I/O-8N 8 outputs. I/O-8N is programmed the same as OUT-1000.
5.8.7
Examples for Output Programming
1. Programming ON/OFF output:
7
ENTR
ENTR
NEXT
ENTR
Output Configur.
ENTER/NEXT/END
ON/OFF Output
ENTER/NEXT/END
X4
Part. For OUT 1
+++----++---+++
PD
-+
ENTR
Pick an output
Set output type
Enable partitions to
activate the output type
Set output’s polarity
& active in disarm
ON/OFF Output
Armed
The procedure is as follows: you first pick a physical output. Then you determine what
output type will trigger it. In this case, the default output type is ‘Armed’, so when the
system is armed, this output is triggered. Then you determine from within which
partition/s this output can be triggered. Then you set the rest.
2. Set ALARM output to “follow open zone” zone type. As a result, when a zone of this
type is opened, the ALARM output is triggered:
7
ENTR
ENTR
NEXT
ENTR
Output Configur.
ENTER/NEXT/END
ALARM Output
ENTER/NEXT/END
X5
Part. For OUT 1
+++----++---+++
PD
-+
ENTR
Set output type
Enable partitions to
activate the output type
Set output’s polarity
& active in disarm
ON/OFF Output
Zone Open