Chapter 3 - Powering on the Mosport 1TE/2TE
RESET/DEFAULT Button
20
Mosport 1TE/2TE
At Start-Time
You can use the
RESET/DEFAULT
button at start-time – you power the unit off, and then depress the button
until the LEDs stop blinking and remain ON. This applies the “Factory Reset” procedure (see
“Factory Reset”
on page 20
). This feature reverts the Mosport 1TE/2TE back to its default factory settings.
Partial Reset
The Partial reset provides a way to contact the Mosport 1TE/2TE in a known and static state while keeping
most of the configuration unchanged.
Following a partial reset, the Mosport 1TE/2TE management interface is set to the
Rescue
interface. The
default address for this interface is 192.168.0.1/24. Any existing network interface that conflicts with the
Rescue interface address is disabled.
You can contact the Mosport 1TE/2TE at this address to access its configuration parameters. It is not advised
to access the unit on a regular basis through the
Rescue
network interface. You should reconfigure the unit’s
network interfaces as soon as possible in order to access it through another interface. See
“After a Partial
Reset” on page 20
for more details.
In a partial reset, the following services and parameters are also affected:
AAA service: User(s) from profile are restored with their factory password.
SNMP service: Resets the
enableSnmpV1
,
enableSnmpV2
,
enableSnmpV3
and
snmpPort
values to their default values.
WEB service: Resets the
serverPort
to its default value.
To trigger the Partial Reset:
1.
Insert a small, unbent paper clip into the
RESET/DEFAULT
hole located at the rear of the Mosport
1TE/2TE. While pressing the
RESET/DEFAULT
button, restart the unit.
Do not depress before all the LEDs start blinking (between 7-11 seconds).
2.
Release the paper clip.
After a Partial Reset
Following a partial reset, you should:
1.
Create or activate network interfaces as described in the
Software Configuration Guide
, Chapter
Interface Parameters
, Section
Interfaces Configuration
. Do not disable the
Rescue
interface!
2.
Change the Mosport 1TE/2TE system management network interface to something other than
Rescue as described in the
Software Configuration Guide
, Chapter
Miscellaneous – Management
Interface
, Section
Management Interface Configuration
.
Note that you must be able to contact the interface you select in order to continue with the following
steps.
3.
Contact the Mosport 1TE/2TE through the new system management network interface.
4.
Disable the
Rescue
network interface as described in the
Software Configuration Guide
, Chapter
Interface Parameters
, Section
Interfaces Configuration
.
Factory Reset
The Factory reset reverts the Mosport 1TE/2TE back to its default factory settings. It deletes the persistent
MIB values of the unit, including:
The firmware pack download configuration files.
The SNMP configuration, including the SNMPv3 passwords and users.
The PPPoE configuration, including the PPP user names and passwords.
The Factory reset creates a new configuration file with the default factory values. It should be performed with
the Mosport 1TE/2TE connected to a network with access to a DHCP server. If the unit cannot find a DHCP
server, it sends requests indefinitely.
Содержание Mosport 1E-F
Страница 6: ...Contents vi Mosport 1TE 2TE...
Страница 10: ...Preface About this Manual Document Conventions x Mosport 1TE 2TE...
Страница 32: ...Chapter 3 Powering on the Mosport 1TE 2TE Management Choices 22 Mosport 1TE 2TE...
Страница 35: ...Disclaimers Hardware Installation Guide Mosport 1TE 2TE 25 RoHS China...
Страница 40: ...Appendix A Standards Compliance and Safety Information Safety Recommendations 30 Mosport 1TE 2TE...
Страница 52: ...Appendix C Standard Hardware Information Warranty 42 Mosport 1TE 2TE...
Страница 56: ...Appendix D Interface Card Installation Instructions Interface Card Installation Instructions 46 Mosport 1TE 2TE...
Страница 60: ...Appendix E Glossary Wide Area Network WAN 50 Mosport 1TE 2TE...
Страница 62: ...Appendix F List of Acronyms 52 Mosport1TE 2TE...