Reset
Pin X1D32 on the phyCORE-Connector is designated as reset input/output.
If used as reset input a hard reset of the module can be triggered. In this case the external
reset signal is connected to the nRESETREQ signal of the DA9062 PMIC which triggers a
hard reset of the module with a debouncing time of 10.24 ms.
When used as reset output, the nRESET signal of the DA9062 PMIC is brought out to allow
resetting devices on the carrier board.
In case of a hard reset, no matter if it was triggered externally or internally, the PMIC holds
down the nRESET signal until the module voltages are generated. The nRESET signal is
released 2 ms after the last module voltage is generated correctly.