100-264Vac Power Supply

Accessory Board for

DMS-30PC/LCD Panel Meters

DMS-EB-AC/DC

?

Allows meters to operate from 100
 to 240Vac (50/60Hz)

?

Screw-type terminal block connections

?

Provides 1500V isolation between AC
supply and input signal

?

Has prototyping features of the standard

DMS-EB board

?

On-board solder gaps for decimal

point placement

?

Same size as DMS-30/40 meters
2.02" (51.3mm)L x 0.82" (20.8mm)W

?

Low cost

This low-cost accessory board provides an easy way of powering all DMS-

30PC-X-RL (

red low-power models only

), as well as all DMS-30LCD and DMS-

40LCD (

non-backlit, +5V-powered models only

) panel meters from 100-264Vac

(50/60Hz). The on-board AC/DC converter provides an is5Vdc to power the
meter’s electronics, while providing 1500Vac isolation between the AC supply and
the input signal being measured. Line power and input signals connect to two
rugged, screw-style terminal blocks (TB1 & TB2) permanently mounted on the
DMS-EB-AC/DC. This type of terminal block provides reliable mechanical connec-
tions and eliminates the need for any extra wiring harness connectors.

The DMS-EB-AC/DC board includes provisions for installing several user-

supplied components that are required when the meter must be scaled to display
non-standard input ranges. The DMS-EB-AC/DC has provisions for such common
applications as attenuation of high input voltages, gain (span) and offset (zero)
adjustments, and direct decimal point placement. The DMS-EB-AC/DC is compat-
ible with all four input versions of the DMS-30 Series meters (±200mV, ±2V, ±20V
and ±200V). Solder gaps, conveniently placed on the board, are easily bridged or
cut to configure the board to meet each application’s specific requirements.

Refer to Mechanical Layout drawing for components and

solder gap location.

Components are user-supplied and not part of the

standard product.

R4 and R5 are part of the resistor accessory kit RN-DMS
(see ordering information)

SG5 is not used

Order on-line at www.datel.com

R3

R 5

10.5k

50k

R4
2k

SG7

SG11

  R 1

R2

SG10

SG14

SG6

SG9

SG8

SG4

SG12

SG3

SG2

SG1

(–) INPUT LO

(+) INPUT HI

ANALOG

COMMON

+1.23V 

REF. OUT

REF. OUT/DP4

REF. IN

+V

OUT

+V

I N

–V

IN

–V

OUT

DC/DC

CONVERTER

+

12

11

8

7

10

9

3   

4   

5   

6   

2   

1   

TB2

1

2

1

2

Closed solder gap

Open solder gap

DP 3

DP 2

DP 1

5V
RETURN

+5V
SUPPLY

HI

(+)

LO
(–)

AC
LO

AC

HI

TB1

SG13

NEW DESIGN!

Wider Operating Range

1500V Isolation, Easier To Modify

Содержание DMS-EB-AC/DC

Страница 1: ...es reliable mechanical connec tions and eliminates the need for any extra wiring harness connectors The DMS EB AC DC board includes provisions for installing several user supplied components that are required when the meter must be scaled to display non standard input ranges The DMS EB AC DC has provisions for such common applications as attenuation of high input voltages gain span and offset zero...

Страница 2: ...d 2 LO 2 Grounding Isolation Because DMS 30 and DMS 40 meters are housed in a plastic case a connection to AC earth ground is not required When wired per the instructions above the DMS EB AC DC board provides a minimum of 1500V isolation between its AC supply input TB2 and its input signal TB1 However please keep in mind that in many applica tions the LO side of the input signal may be connected t...

Страница 3: ...t Placement DATEL ships the DMS EB AC DC with all decimal point solder gaps SG1 SG2 SG3 and SG4 open To enable a specific decimal point close its respective solder gap with solder When reassigning decimal places for subsequent applications remember to open any previously closed solder gaps Close SG1 for 1 999 DP1 Close SG2 for 19 99 DP2 Close SG3 for 199 9 DP3 Close SG4 for 1999 9 DP4 on DMS 40LCD...

Страница 4: ...n only carry currents up to 0 2A 200mA However dc currents up to 2A can be accommodated if a 20AWG jumper wire is soldered in location R1 Be sure R2 has a sufficient power rating to safely carry the full load current Refer to DMS Application Note 6 for more information on dc ammeters 1 Install R2 R2 FSR IMAX x 10000 where FSR is the desired meter reading 0 up to 1999 disregarding any decimal point...

Страница 5: ...This datasheet has been downloaded from www DatasheetCatalog com Datasheets for electronic components ...

Отзывы: