Pin
Description
©
PHYTEC Messtechnik GmbH 2016 L-808e_2
9
Note:
•
Most of the controller pins have multiple multiplexed functions. As most of these pins
are connected directly to the phyCORE-Connector the alternative functions are
available by using the i.MX 6's pin muxing options. Signal names and descriptions in
to
however, are in regard to the specification of the phyCORE-i.MX 6 and
the functions defined therein. Please refer to the
i.MX 6 Reference Manual
, or the
schematic to get to know about alternative functions. In order to utilize a specific pin's
alternative function the corresponding registers must be configured within the
appropriate driver of the BSP.
•
The following tables describe the full set of signals available at the phyCORE-Connector
according to the phyCORE-i.MX 6 specification. However, the •
If the phyCORE-i.MX 6 is delivered with a carrier board (e.g. the phyBOARD-Mira) the
pin muxing might be changed within the appropriate BSP in order to support all
features of the carrier board. If so, information on the differences from the pinout
given in the following tables can be found in the carrier board's documentation.