phyCORE
®
-i.MX 6 [PCM-058]
14
©
PHYTEC Messtechnik GmbH 2016 L-808e_2
Pin #
Signal
ST
Voltage Domain
Description
C1
X_BOOT_MODE0
I
VDD_3V3_LOGIC
Boot mode input 0
C2
X/TX0+
ETH_O
VDD_3V3_LOGIC
ETH0 data A+/t
C3
X_ETH0_A-/TX0-
ETH_O
VDD_3V3_LOGIC
ETH0 data A-/transmit-
C4
GND
-
-
Ground 0 V
C5
X
ETH_I/O
VDD_3V3_LOGIC
ETH0 data C+ (only GbE)
C6
X_ETH0_C-
ETH_I/O
VDD_3V3_LOGIC
ETH0 data C- (only GbE)
C7
X_ETH0_LED0
OC
VDD_3V3_LOGIC
ETH0 link LED output
C8
X_SATA_TXP
LVDS_O
i.MX6 internal
SATA PHY transmit lane+
C9
X_SATA_TXN
LVDS_O
i.MX6 internal
SATA PHY transmit lane-
C10
GND
-
-
Ground 0 V
C11
X_PC
PCIe_O
i.MX 6 internal
PCIe clock lane+
C12
X_PCIe0_CLK-
PCIe_O
i.MX 6 internal
PCIe clock lane-
C13
X_PCIe_RXP
PCIe_I
i.MX 6 internal
PCIe receive lane+
C14
X_PCIe_RXN
PCIe_I
i.MX 6 internal
PCIe receive lane-
C15
GND
-
-
Ground 0 V
C16
X_SPDIF_OUT
O
VDD_3V3_LOGIC
SPDIF output
C17
X_PWM1_OUT
O VDD_3V3_LOGIC
PWM1
output
C18
X_USB_OTG_ID
I
VDD_3V3_LOGIC
USB OTG ID Pin
C19
X_USB_OTG_VBUS
PWR_I
5 V
USB OTG VBUS input
C20
X_USB_OTG_PWR
O
VDD_3V3_LOGIC
USB OTG power enable
C21
GND
-
-
Ground 0 V
C22
X_CCM_CLKO2
O
VDD_3V3_LOGIC
CCM clock output 2
C23
X_USB_H1_DP USB_I/O
i.MX
6
internal USB
Host1
data+
C24
X_USB_H1_DN
USB_I/O i.MX 6 internal
USB Host1 data-
C25
GND
-
-
Ground 0 V
C26 X_PMIC_nSHUTDOWN
I
VDD_3V3
PMIC
shutdown
C27
X_3V3_GOOD
O
VDD_MX6_SNVS
3V3 power good signal
C28
X_JTAG_TMS I
VDD_3V3_LOGIC
JTAG
TMS
C29
X_JTAG_TDO O
VDD_3V3_LOGIC
JTAG
TDO
C30
X_CSI_D0P
CSI2_I
i.MX 6 internal
MIPI/CSI-2 data0+
C31
X_CSI_D0M
CSI2_I
i.MX 6 internal
MIPI/CSI-2 data0-
C32
GND
-
-
Ground 0 V
C33
X_CSI_D2P
CSI2_I
i.MX 6 internal
MIPI/CSI-2 data2+
C34
X_CSI_D2M
CSI2_I
i.MX 6 internal
MIPI/CSI-2 data2-
C35
X_CSI_CLK0P
CSI2_I
i.MX 6 internal
MIPI/CSI-2 clock+
C36
X_CSI_CLK0M
CSI2_I
i.MX 6 internal
MIPI/CSI-2 clock-
C37
GND
-
-
Ground 0 V
Table 5:
Pinout of the phyCORE-Connector X1, Row C
Содержание phyCORE-i.MX 6
Страница 14: ...phyCORE i MX 6 PCM 058 xii PHYTEC Messtechnik GmbH 2016 L 808e_2...
Страница 33: ...Jumpers PHYTEC Messtechnik GmbH 2016 L 808e_2 19 Figure 6 Jumper Locations top view J6 J3 J4...
Страница 78: ...phyCORE i MX 6 PCM 058 64 PHYTEC Messtechnik GmbH 2016 L 808e_2...
Страница 82: ...Published by PHYTEC Messtechnik GmbH 2016 Ordering No L 808e_2 Printed in Germany...