Hardware Description |
33
Communications (connectors S1, C1, X1 e X2):
»
serial asynchronous interface RS232 / RS422 / RS485
»
CiA CANOpen DS301 / DSP402 V4.02 fieldbus interface
»
EtherCAT (COE) real-time ethernet fieldbus
4.3
HARDwARe
»
IP 20 Cabinet protection, with internal RFI shield,
»
Control and power interfaces with removable terminals and connectors,
»
Encoder and serial interface with D standard connectors,
»
Integrated ground bar (3xM4) for shields and groundings.
4.4
leD
DISPlay
Led meaning
During the drive’s normal work, the following operating conditions are monitored on the led
display (more than one led can light together).
Drive condition
Leds on
Lighting mode
Description
Alarm
0, 1, 2,
3, 4
Fix
Display the binary code of the active alarm.
Refer to chap. 9 for codes description
S
1 Hz flashing
Drive condition
Led on
Lighting mode
Description
Drive Ok
E
1Hz flashing
Drive’s normal run.
Disabled.
2 fast flashing every
500ms
Drive’s normal run.
Enabled.
Field Bus
Communication
C
Variable frequency
flashing
The drive is connected to a field bus line. Flashing
every data received.
4
3
2
1
0
S
C
e
4
3
2
1
0
Normal work conditions
When the drive is in “alarm” or “error” condition, all run condition signals are cancelled: the
leds show the alarm codes only.
Alarm conditions
Status
Enable
Communications
AxM-II (2011-10).indd 33
18/10/11 15:15
Содержание AxM II 04.09.4
Страница 4: ...AxM II 2011 10 indd 6 18 10 11 15 15...
Страница 20: ...AxM II 2011 10 indd 22 18 10 11 15 15...
Страница 24: ...AxM II 2011 10 indd 26 18 10 11 15 15...
Страница 28: ...AxM II 2011 10 indd 30 18 10 11 15 15...
Страница 32: ...AxM II 2011 10 indd 34 18 10 11 15 15...
Страница 58: ...AxM II 2011 10 indd 60 18 10 11 15 15...
Страница 64: ...AxM II 2011 10 indd 66 18 10 11 15 15...
Страница 70: ...AxM II 2011 10 indd 72 18 10 11 15 15...
Страница 80: ...AxM II 2011 10 indd 82 18 10 11 15 15...
Страница 83: ...Appendix 85 AxM II 2011 10 indd 85 18 10 11 15 15...
Страница 84: ...AxM II 2011 10 indd 86 18 10 11 15 15...