Ce Conformity |
69
4. The drives correspond to the LVD 73/23/EWG
9.5
insTAllATion
1. The units must be installed and cooled according to the regulations stated in the cor-
responding documentation
2. Ensure that no components are bent or insulation distances changed during transport.
The electronic components and contacts must not be touched.
3. When working on an energized controller the valid national requirements for the preven-
tion of accidents must be observed.
4. The electrical installation must comply with applicable regulations (cable cross sections,
fuses, protective conductor connections)
5. All control inputs and outputs of the drives are insulated with a “basic” insulation (func-
tional). Another level of protection must be implemented for personal safety against
electrical contact..
6. When using current-operated protective devices, please note that:
The controller have internal DC rectification. A DC fault current is therefore possible.
Some differential current protection systems are made inoperative by DC current leakage.
Use only “universal” or pulse operated protection devices.
The RFI filter which is built into the drives cause a certain amount of leakage current
to flow in the ground wires. This current may cause tripping of too sensitive differential
device and need to be taken into account while sizing differential devices.
7. Irrespective of the CE mark on both drives and motors, it is reminded that the compliance
of the required limit values with the legal EMC regulations remain the responsibility of
the manufacturer of the system or machine.
9.6 eC
DeClARATion oF ConFoRmiTy
aND
DiReCTiVe emCD
Ref. to EC Low Voltage Directive 72/23/EWG
ULTRACT III series motors and AxM II / AxP series brushless amplifier are designed, manu-
factured and tested in conformity with the EC Low Voltage Directive 72/23/EWG and under
the responsibility of:
Phase Motion Control S.p.A., Via Adamoli 461, 16141 Genova
The applied standards are the following:
IEC 34-1, 34-5,34-6, 34-11, 34-14 e IEC 72;
EN 60529
IEC 249/1 10/86,
IEC 249/2 15/12/89
IEC 326/1 10/90,
EN 60097/9.93
The EMCD Directive (89/336EWG)
The EMCD directive relating to electromagnetic compatibility is effective for “equipment”
which may either cause electromagnetic disturbances or be affected by such disturbances.
The aim is the limitation of the generation of electromagnetic disturbances so that the op-
AxM-II (2011-10).indd 69
18/10/11 15:15
Содержание AxM II 04.09.4
Страница 4: ...AxM II 2011 10 indd 6 18 10 11 15 15...
Страница 20: ...AxM II 2011 10 indd 22 18 10 11 15 15...
Страница 24: ...AxM II 2011 10 indd 26 18 10 11 15 15...
Страница 28: ...AxM II 2011 10 indd 30 18 10 11 15 15...
Страница 32: ...AxM II 2011 10 indd 34 18 10 11 15 15...
Страница 58: ...AxM II 2011 10 indd 60 18 10 11 15 15...
Страница 64: ...AxM II 2011 10 indd 66 18 10 11 15 15...
Страница 70: ...AxM II 2011 10 indd 72 18 10 11 15 15...
Страница 80: ...AxM II 2011 10 indd 82 18 10 11 15 15...
Страница 83: ...Appendix 85 AxM II 2011 10 indd 85 18 10 11 15 15...
Страница 84: ...AxM II 2011 10 indd 86 18 10 11 15 15...