8
|
Axm ii / AxP
Configurable Motion Control Platform
1.1 axM II -
size 1
148
65,50
78,5
5
8
166,5
5,50
21
5,50
19,5
126 0,20
Install inside a switchboard avoiding any obstacle for cooling fan air flux. To avoid any de-
rating of the product performance, do not place objects less than 10 mm from the cooling
plateside.
The inner temperature of the switchboard must doesn’t exceed 40°C.
Cooling air flux
To assure to the fan the requested “breath-
ing” and thus the proper cooling of the heat
sink, the distance between the heat sink
edge and the nearest flat surface (e.g. oth-
er drives, cabinet wall,…) must be at least
10mm.
The fan is automatically switched on when
the heat sink temperature reaches 50° C.
Overall dimensions and space required for installation
AxM-II (2011-10).indd 8
18/10/11 15:15
Содержание AxM II 04.09.4