File: 2240.doc - 03/11/03 14:27
R. N 141516 A.1 A.2
1 9 1 1 1 1998 3014
2 0 0 0 0 0 0
3 0 0 0 0 0 0
On the R column appears the number of the memorised line.
(99 different profiles can be memorised)
On the N column appears the number of the milling cutter to be used (from 1 to 9)
The columns 14, 15 and 16 indicate the status of the limit switch sensors 14 15 and 16.
On columns A.1 and A.2 are given the values of the potentiometers for the horizontal and
vertical locking.
To cancel a line move the cursor on that line by means of the arrow and press on F3,
then confirm moving the cursor to YES and pressing ENTER.
To cancel the whole archive press F4, then confirm moving the cursor to YES and
pressing ENTER.
IMPORTANT! ALL THE ACQUIRED DATA WILL BE LOST.
7. NOISE
Tests were carried out in conformity with the specifications of Directive 89/392 Encl. I, Article
1.7.4, point f, with measurements made in accordance with ISO 3746 standards
The test conditions and results are given in the enclosure 7 of this instruction manual.
The operator is advised to use protective equipment, such as good quality soundproofed ear
guards.
To prevent the exposure level from increasing beyond the test values over time, check the
sharpening status of the milling cutter groups constantly.
In relation with the use of the machine, it is not possible to be sure that the level of personal
exposition be less than 85 dB(A). It is necessary to carry out some internal tests, directly in the
place where the machine works, on the acoustic emission with relation to the exposure time as
this limit value could be overcome.
In the ENCLOSURE 7 is given, as well as the test conditions and the resulted values,
information material concerning the sound, in conformity with the article 46 of the Leg. Decree
277/91.
MANUALE D’ISTRUZIONE PER L’USO E LA
MANUTENZIONE PULITRICE AUTOMATICA CM4S
38