DWG. A1.32
IMPORTANT!!! PERTICI S.p.A. ACCEPTS NO LIABILITY IN CASE TOOLS ARE USED,
WHICH DO NOT HAVE THE SPECIFICATIONS DESCRIBED AND REQUIRED IN THIS
INSTRUCTION MANUAL.
8.3 – Replacement of knifes for welding seal removal
To replace the knife for the welding seal removal, turn the main switch to position “0” and
disconnect the pneumatic equipment by acting on the disconnecting valve.
- Upper knife 1
(DWG. A1.33):
open the right openable panel
(DWG. A1.1)
and manually move
the upper knife support towards the milling packs. Loosen the headless screw 2
(DWG. A1.33),
using the 4 mm hexagonal key supplied.
2
1
DWG. A1.33
MANUALE D’ISTRUZIONE PER L’USO E LA
MANUTENZIONE PULITRICE AUTOMATICA CM4S
41
File: 2240.doc - 03/11/03 14:27