DWG. A1.28
The number given in the drawing
(DWG. A1.28)
indicates the number of the milling cutter pack
being regulated.
6.3 Adjustment and replacement of knifes for welding seal removal
The CM4-S has two knifes for the welding seal removal (an upper and a lower one), which are
regulated by the PERTICI SPA during the acceptance test, and that should not need any further
regulation. Anyway, should it be necessary to carry out the adjustment of their working depth,
proceed as follows:
- turn the main switch to position “0” to remove power from the machine;
- act on the disconnecting valve to cut the air off from the pneumatic equipment;
- Upper knife:
- open the upper right lateral panel
(DWG. A1.1)
and move the support of the upper knife
manually in the direction of the milling pack groups.
- partially loosen the nut 1
(DWG. A1.29)
and carry out the regulation by turning the screw 2
(DWG. A1.29).
By turning it clockwise the working depth diminishes, while by turning it counter
clockwise the working depth increases.
- screw the nut completely 1
(DWG. A1.29),
to fix the adjustment that has been carried out.
2
1
DWG. A1.29
MANUALE D’ISTRUZIONE PER L’USO E LA
MANUTENZIONE PULITRICE AUTOMATICA CM4S
34
File: 2240.doc - 03/11/03 14:27