SMART I/O User’s Manual
October 01, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 104
Chapter 5 Analog Modules
O_ENABLE_LINE_CHECK
:
This operate call allows the user to enable open-
loop checking on the current version of the SM-
ADC1. The syntax is as follows:
<analog var> := OPERATE(<iovar>, O_ENABLE_LINE_CHECK,
<var>);
where
<analog var>
represents the analog return variable and can
be zero if the operate call is supported and the
correct
<iovar>
is passed or non-zero if an
error occurred.
<iovar>
is the variable name for the channel where the
operate call is to take effect.
<var>
is not used.
O_DISABLE_LINE_CHECK
:
This operate call allows the user to disable open-
loop checking on the current version of the SM-
ADC1. The syntax is as follows:
<analog var> := OPERATE(<iovar>, O_DISABLE_LINE_CHECK,
<var>);
where
<analog var>
represents the analog return variable and can
be zero if the operate call is supported and the
correct
<iovar>
is passed or non-zero if an
error occurred.
<iovar>
is the variable name for the channel where the
operate call is to take effect.
<var>
is not used.
Содержание Modular Computers RS232
Страница 2: ...This page was intentionally left blank ...
Страница 12: ...This page was intentionally left blank ...
Страница 18: ...SMART I O User s Manual March 12 1996 1996 PEP Modular Computers GmbH Page 1 6 Introduction ...
Страница 89: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 1 Manual ID 09901 Rev Index 0500 Digital Modules ...
Страница 92: ...This page was intentionally left blank ...
Страница 143: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 57 Manual ID 09901 Rev Index 0500 Figure 4 3 Solder Side ...
Страница 149: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 63 Manual ID 09901 Rev Index 0500 Figure 4 7 Connection ...