SMART I/O User’s Manual
October 01, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 98
Chapter 5 Analog Modules
5.4.8.5 SMADC1SetLed
Syntax
error_code SMADC1SetLed(u_int8 PortNr, u_int8 LedNr);
Description
This function switches on one of the two LEDs fitted to the SM-ADC1.
Input
u_int8 PortNr
SM-Port number to be accessed
u_int8 LedNr
Number of the LED to switch on (1-2)
Output
error_code
SUCCESS
E_SEEK
if module was not initialised
E-BMODE
if the module is unknown
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADC1SetLed(0, 2);