SMART I/O User’s Manual
March 12, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 52
Chapter 5 Analog Modules
5.2.8.15 SMADCEnableConversion
Syntax
error_code SMADCEnableConversion(u_int8 PortNr, u_int8
channel, BOOLEAN enable);
Description
This function checks if an SM-PT100 board is fitted on the specified port and
if the channel is valid and forces the HW task to convert the raw values. If
the flag
enable
is TRUE (<>0), then conversion of raw values to degrees
Celsius is executed, else if (
enable
=FALSE) no conversion takes place. The
function invalidates converted data, if enable is set to FALSE.
Input
u_int8 PortNr
Port number to enable data conversion
(from 0 to 10)
u_int8 channel
Number of specified channel (0 to 3)
BOOLEAN enable
Flag for enabling or disabling conversion of
raw values
Output
error_code
SUCCESS
E_MNF
If wrong type of module or no module
is fitted on the selected port
E_PARAM
If wrong channel number is specified
E_BMODE
If conversion can’t be enabled because
a bad or no sensor type is specified
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCEnableConversion(0, 1, FALSE);
Содержание Modular Computers RS232
Страница 2: ...This page was intentionally left blank ...
Страница 12: ...This page was intentionally left blank ...
Страница 18: ...SMART I O User s Manual March 12 1996 1996 PEP Modular Computers GmbH Page 1 6 Introduction ...
Страница 89: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 1 Manual ID 09901 Rev Index 0500 Digital Modules ...
Страница 92: ...This page was intentionally left blank ...
Страница 143: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 57 Manual ID 09901 Rev Index 0500 Figure 4 3 Solder Side ...
Страница 149: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 63 Manual ID 09901 Rev Index 0500 Figure 4 7 Connection ...