Chapter 5 Analog Modules
5.3.8.7 SMADCSetPrecision
Syntax
error_code SMADCSetPrecision(u_int8 PortNr, u_int8
channel, u_int8 precision);
Description
This function checks if an SM-THERM board is fitted on the specified port
and if the channel is valid. It sets the precision of the AD Converter. The
valid precision values are defined in the file
smadc.h
. Note that large preci-
sion/filter values cause longer AD conversion times.
Input
u_int8 PortNr
Port number to set precision
(from 0 to 10)
u_int8 channel
Number of specified channel (0 to 3)
u_int8 precision
Resolution of ADC; filter value
Output
error_code
SUCCESS
E_MNF
If wrong type of module or no module
is fitted on the selected port
E_PARAM
If wrong channel number is specified
E_BMODE
Illegal precision value (must be within
19 to 2000).
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCSetPrecision(0, 1, 0x100);
Содержание Modular Computers RS232
Страница 2: ...This page was intentionally left blank ...
Страница 12: ...This page was intentionally left blank ...
Страница 18: ...SMART I O User s Manual March 12 1996 1996 PEP Modular Computers GmbH Page 1 6 Introduction ...
Страница 89: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 1 Manual ID 09901 Rev Index 0500 Digital Modules ...
Страница 92: ...This page was intentionally left blank ...
Страница 143: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 57 Manual ID 09901 Rev Index 0500 Figure 4 3 Solder Side ...
Страница 149: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 63 Manual ID 09901 Rev Index 0500 Figure 4 7 Connection ...