4.3.8.6 SMREL1SetRly
Syntax
error_code SMREL1SetRly(u_int8 PortNr,
u_int8 *buffer);
Description
This function sets the output of the port
PortNr
with the
buffer
contents.
Bits 0-5 of the buffer are used to set the Relays:
0 = close relay
1 = open relay
Bits 6 and 7 have no function.
Input
u_int8 PortNr
SM-Port number to set data
u_int8 *buffer
Pointer to buffer where data is stored
Output
error_code
SUCCESS
E_BMODE
if the module is unknown
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMREL1SetRly(0, buffer);