Digital Modules
08 Jan. 98
SMART I/O User’s Manual
Page 4 - 51
Manual ID 09901, Rev. Index 0500
A complete list of the operate COMMANDS may be obtained
by selecting a project from the ISaGRAF projects group, open-
ing an application and observing the Common defines in the Dic-
tionary pull-down menu. Note that not all calls in the list may be
used within the SMART I/O environment. However, the calls
applicable to this module are:
O_INIT_CODE
Syntax and usage as explained above.
O_SET_LED
This operate call allows the user to control the yellow LED on
the board’s front panel. The syntax is as follows:
<analog var> := OPERATE(<iovar>, O_SET_LED,
<var>);
where
<analog var>
represents the analog return variable and can
be zero, if the operate call is supported and the
correct
<var>
is passed, or non-zero, if an
error occurred.
<iovar>
represents any module variable, and
<var>
represents the LED to be controlled and must
be one of
OA_LED1_ON
or
OA_LED1_OFF
.
O_EXT_POWER
This operate call can detect whether the external power has
failed or not, and has the following syntax:
<analog var> := OPERATE(<iovar>,
Содержание Modular Computers RS232
Страница 2: ...This page was intentionally left blank ...
Страница 12: ...This page was intentionally left blank ...
Страница 18: ...SMART I O User s Manual March 12 1996 1996 PEP Modular Computers GmbH Page 1 6 Introduction ...
Страница 89: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 1 Manual ID 09901 Rev Index 0500 Digital Modules ...
Страница 92: ...This page was intentionally left blank ...
Страница 143: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 57 Manual ID 09901 Rev Index 0500 Figure 4 3 Solder Side ...
Страница 149: ...Digital Modules 08 Jan 98 SMART I O User s Manual Page 4 63 Manual ID 09901 Rev Index 0500 Figure 4 7 Connection ...