EI65 OPERATOR’S AND CALIBRATION MANUAL
L-B B5L0082/PAT 031-300-190-015 REVISION D 04/15/99
14
STEP 3
The actual value of the Minimum Boom Angle Preset is displayed.
To enter a new value of the Minimum Boom Angle Preset, the operator has to push the
button “UP” (12) for increase and the button “DOWN” (11) for decrease the displayed value.
If the crane operator wants to continue with the displayed value, he has to confirm by
pushing the button “OK” (10).
Push Button “OK” (10) for next step.
STEP 4
The actual value of the Maximum Boom Angle Preset is displayed.
To enter a new value of the Maximum Boom Angle Preset, the operator has to push the
button “UP” (12) for increase and the button “DOWN” (11) for decrease the displayed value.
If the crane operator wants to continue with the displayed value, he has to confirm by
pushing the button “OK” (10).
Push Button “OK” (10) for next step.
STEP 5
For verification of the previously set values the Maximum and Minimum Boom Angle Preset is
displayed.
Push Button “OK” (10) for next step.
STEP 6
The Setting Procedure for the Boom Angle Presets is completed. The display shows the actual
crane data. To remind the crane operator of the activated Boom Angle Preset the display of
the actual boom angle shows a intermittent colon.