OPERATOR’S SECTION
L-B B5L0082/PAT 031-300-190-015 REVISION D 04/15/99
9
If there is a difference between the indicated and the actual condition, the operator must
correction those values by completing step 1 to 14 in Section 4.2.2.
The system stores the preset values for minimal 2 hours when the crane voltage is switched
off. After a loss of the preset values the operator will need to reset these values.
The display shows the previously programmed boom and jib
configuration. The crane operator can compare the preset
Operating Configuration Values with the actual crane
configuration. To confirm the displayed values push the button “OK” (10).
To change the configuration values go to one of the following sections.
If the system
configurations are correct, go to Section
5 PRE-OPERATION INSPECTION
.
•
Section 4.2 will allow the operator to change all crane configurations.
•
Section 4.2.1 will allow the operator to quickly change Reeving only
•
Section 4.2.2 will allow the operator to quickly to change Hoist selection only.
Setting Operating Configuration of the Crane
STEP 1
To enter new values the button “Select” (6) has to be pushed.
The DOWN (11) button can be pressed to skip a step in the following procedure. When the a
particular step is skipped, the configured values of that step remain the same as the
confirmed values in Section 4.1
STEP 2
The operator is requested to enter the boom configuration. To enter
new boom data he has to push the button “OK” (10).
Push Button “OK” (10) for next step.
To continue with the previously entered boom configuration the button DOWN (11) has to be
pushed.
Step 3 to 9 will be skipped, when the button “DOWN” is pressed.
STEP 3
The operator is requested to push the button “DOWN” (11) if the
crane is equipped with a boom extension.
If the crane is equipped only with a main boom (without jib or boom extension) the button OK
(10) has to be pressed.
Step 5 to 9 will be skipped, when the button “OK” is pressed.
MB 115.0 J1 85.0
J2 50.0 0J 15.0 1
SELECT BOOM?
PUSH
↓
OR OK
MAIN BOOM?
PUSH
↓
OR OK