![Parker Compumotor ZETA6104 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/parker/compumotor-zeta6104/compumotor-zeta6104_installation-manual_3861903013.webp)
6
z
ZETA6104 Installation Guide
Mounting the ZETA6104
Before you mount the ZETA6104
Check the list below to make sure you have performed all the necessary configuration tasks that require
accessing internal components (DIP switches, potentiometers, and jumpers). You may, however, be able to
adjust DIP switches and pots after mounting, if you allow access to the top of the ZETA6104 chassis.
¥
Select motor current (DIP switches)
. If you ordered a ZETA motor with your system (e.g., ZETA6104-57-83) and you
intend to use series motor winding, use the factory setting. If you need to change this setting, refer to page 4 for instructions.
¥
Select device address (DIP switches)
. If you are not connecting multiple ZETA6104 units in an RS-232C daisy chain or an
RS-485 multi-drop, use the factory setting. If you need to change this setting, refer to page 4 for instructions.
¥
Select serial communication method (jumpers & DIP switches)
. If you are using RS-232C to communicate with the
ZETA6104, use the factory settings. If you need to change these settings (i.e., for RS-485), refer to page 5 for instructions.
¥ Be aware that if you exercise the motor matching procedures on page 22, you will need to access the potentiometers at the top
of the ZETA6104 chassis. (The motor matching procedures are placed after the Electrical Connections section of this manual
because the process requires that you first understand how to connect the motor, serial communication, and AC power.)
3x
¯
0.156 (3.9)
(clearance for #6 (M3.5)
mounting screw)
0.965
(24.5)
1.000
(25.4)
1.465
(37.2)
4.000
(101.6)
5.970 (151.6)
6.813 (173.1)
8.600
(218.4)
8.000
(203.2)
8.850
(224.8)
0.133
(3.4)
Dimensions in inches (millimeters).
Environmental
Considerations
Temperature.
Operate the ZETA6104 in ambient
temperatures between 32
°
F (0
°
C) and 113
°
F (45
°
C). Provide a
minimum of 1 inch (25.4 mm) of unrestricted air-flow space
around the ZETA6104 chassis (see illustration). The ZETA6104
will shut itself down if its internal sensor reaches 131
°
F (55
°
C).
Humidity
. Keep below 95%, non-condensing.
Airborne Contaminants, Liquids
. Particulate
contaminants, especially electrically conductive material, such as
metal shavings and grinding dust, can damage the ZETA6104 and
the Zeta motor. Do not allow liquids or fluids to come in
contact with the ZETA6104 or its cables.
1.0
(25.4)
1.0 (25.4)
Minimum Airflow Space = 1 inch
1.0 (25.4)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание Compumotor ZETA6104
Страница 45: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 49: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 53: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 63: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...