Chapter 1. Installation
1 5
INPUT CONNECTIONS —
Connecting to electronic devices such as PLCs
Connection to a
Sinking Output
D e v i c e
Connection to a
Sourcing Output
D e v i c e
Connection to a
Combination of
Sinking &
Sourcing
O u t p u t s
Electronic
Device
Out 5-24 Volts
ISO GND
74HCTxx
6.8 K
Ω
47 K
Ω
Input
Connection
Ground
Connection
Output
Ground
The output should
be able to sink at
least 1mA of current.
6200
ISO GND
1
2
3
+5VDC
Set Jumper
JU2 to position
2/3 (factory
default
position) for
the inputs to
source current.
(see page 4)
Electronic
Device
Out 5-24 Volts
ISO GND
74HCTxx
47 K
Ω
Input
Connection
Ground
Connection
Output
Ground
OEM6200
V1
R1
6.8 K
Ω
ISO GND
1
2
3
+5VDC
Set Jumper
JU2 to position
1/2 for the
inputs to sink
current.
(see page 4)
Typical value for R = 450
Ω
(assuming R1 = 0)
Note: The value of R may vary depending on the value of R1 and V1.
Electronic
Device
Out 5-24 Volts
ISO GND
74HCTxx
47 K
Ω
Input
Connection
Ground
Connection
Output
Ground
OEM6200
V1
R1
R
6.8 K
Ω
ISO GND
1
2
3
+5VDC
Set Jumper
JU2 to position
2/3 (factory
default
position) for
the inputs to
source current.
(see page 4)
PROGRAMMING TIP
Connecting to a
sinking output? Set the
input’s active level to low
with the
INLVL
command
(
Ø
= active low).
Connecting to a
sourcing output? Set
the input’s active level to
high with the
INLVL
command (
1
= active high).
Thus, when the output is
active, the
TIN
status
command will report a “
1
”
(indicates that the input is
active), regardless of the
type of output that is
connected.
Details on setting the active
level and checking the input
status are provided in the
6000 Series Programmer’s
Guide. Refer also to the
INLVL
and
TIN
command
descriptions in the
6000
Series Software Reference.
NOTE:
If you will be connecting to a combination of sourcing and sinking outputs, set internal
jumper JU2 to position 2/3 so that the inputs source current to
+5V
to accommodate sinking
output devices (factory default setting). (See page 4 for instructions on setting JU2.) Then
for each individual input connected to a sourcing output, wire an external resistor between
the 6200’s programmable input terminal and ground (see “R” in above drawing). The resistor
provides a path for current to flow from the device when the output is active.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание Compumotor 6200
Страница 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 35: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 37: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...