8
6200 Installation Guide
Motor Drivers
PIN OUTS & SPECIFICATIONS
(15-pin DRIVE Connector)
15 D
Pin #
Cable
(71-010432-10)
Color (25 D Pin #) Name
In/Out
Description
1
Red (pin #1)
Step (+)
OUT
Differential output. Step (pulse) output to the drive. Step + signal is active high.
Signal levels: Low
≤
1.0VDC @ -30mA, High
≥
3.5VDC @ +30mA.
2
Green (pin #2)
Direction (+)
OUT
Differential output. High signal on Dir specifies motion in the positive
direction; Low signal on Dir specifies motion in the negative direction.
Signal levels: Low
≤
1.0VDC @ -30mA, High
≥
3.5VDC @ +30mA.
3
—
Reserved
—
-----------------------
4
Gray (pin #10)
In-Position
IN
Used for digital servo drives to indicate that the motor has reached the target
position. TTL switching levels (Low
≤
0.4V, High
≥
2.4V). Voltage range: 0-5V.
5
Yellow (pin #9)
Drive Fault
IN
An active-high (current not flowing) signal that tells the 6200 a drive has faulted. TTL
switching levels (Low
≤
0.4V, High
≥
2.4V). You can use the
DRFLVL
command to
change the active level to low (current flowing) if desired. NOTE: Drive Fault input
will not be recognized until the input functions are enabled with
INFEN1
command.
6
—
Reserved
—
-----------------------
7
—
+5V
OUT
+5V output.
8
Bare Wire (pin #5)
Shield
—
Connected to chassis (earth) ground within the 6200.
9
Black (pin #14)
Step Return (-)
IN
Differential output. Step (pulse) output to the drive. Step - signal is active low.
10
White (pin #15)
Direction Return (-)
IN
Differential output. Low signal on Direction - specifies motion in the positive
direction; High signal on Direction - specifies motion in the negative direction.
11
Blue (pin #16)
Shutdown (+)
OUT
Differential output. This signal is used to turn off current in the motor windings.
High
signal on Sh indicates the motor winding current should be off.
Signal levels: Low
≤
1.0VDC @ -30mA, High
≥
3.5VDC @ +30mA.
12
Purple (pin #17)
Shutdown Return
(-)
IN
Differential output. This signal is used to turn off current in the motor windings.
Low
signal on Shutdown - indicates the motor winding current should be off.
13
Orange (pin #21)
Ground
—
Isolated logic ground
14
Brown (pin #22)
Ground
—
Isolated logic ground
15
—
Reserved
—
-----------------------
INTERNAL SCHEMATICS
Step, Direction & Shutdown Outputs
+5VDC
GND
15-Pin
DRIVE
Connector
Step +
Dir
Sh
Step -
Direction -
Shutdown -
Shutdown Output Circuit Current Flow
(Active vs. Inactive)
Sh
Shutdown -
Current
Flow
(Active)
Current
Flow
(Active)
Current
Flow
(Inactive)
Current
Flow
(Inactive)
Drive Fault and In-Position Inputs
+5VDC
GND
74HCTxx
1 K
Ω
15-Pin
DRIVE
Connector
Drive Fault or
In-Position
Ground
(pin 13 or 14)
15-Pin
DRIVE
Connector
+5VDC
GND
+5VDC
GND
+5VDC
GND
C O N N E C T I O N S
WARNING
Make sure the drive is off before
connecting it to the 6200.
15-pin D
Connector
Drive
Motor
Plug-compatible with most
Compumotor and Digiplan drives
(exceptions are illustrated below).
Connect to DRIVE connector
25-pin D
Connector
Connect to drive
10-foot cables provided in ship kit (p/n 71-010432-10).
Maximum recommended cable length is 50 feet.
Pin outs and cable color code provided in table above.
71-010432-10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание Compumotor 6200
Страница 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 35: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 37: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 41: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...