9.2.6
Z
ONE
A
LARM
R
ESTORE
R
EPORT
C
ODES
Sections [191] to [194]
A report code can be programmed for each of the 15 available zones. The control panel can transmit these report
codes to the central station identifying which zone was restored.
A zone is restored when it closes after generating an alarm or once the bell has cut-off after alarm generation.
Please refer to Zone Restore Report Options on page 38.
9.2.7
S
PECIAL
A
LARM
R
EPORT
C
ODES
Sections [195] and [196]
Whenever the system generates an alarm due to one of the conditions listed below, the control panel can send the
appropriate report code to the central station identifying the type of alarm.
Section [195]
•
E
MERGENCY
P
ANIC
: Panic keys [1] and [3] have been pressed (see page 30).
•
A
UXILIARY
P
ANIC
: Panic keys [4] and [6] have been pressed (see page 30).
•
F
IRE
P
ANIC
: Panic keys [7] and [9] have been pressed (see page 30).
•
R
ECENT
C
LOSING
: Reports when an alarm is generated after arming the system within period defined by the Recent
Close Delay (see page 38).
Section [196]
•
A
UTO
Z
ONE
S
HUTDOWN
: A zone communicates more than the programmed number of transmissions in a single
armed period (see page 20).
•
D
URESS
: A Duress access code is keyed in (see page 15).
•
K
EYPAD
L
OCKOUT
: If a consecutive number of invalid codes are entered into a keypad, the control panel can be set
to deny access from all keypads for a specified period.
•
Future use
9.2.8
Z
ONE
T
AMPER
R
EPORT
C
ODES
Section [197] to [200]
A report code can be programmed for each of the 15 available zones. Whenever a tamper or wire fault occurs on a
zone, the control panel can send the appropriate report code to the central station identifying which zone was
tampered.
9.2.9
Z
ONE
T
AMPER
R
ESTORE
R
EPORT
C
ODES
Sections [201] to [204]
A report code can be programmed for each of the 15 available zones. Whenever a tampered zone is restored, the
control panel can send the appropriate report code to the central station identifying which zone has been restored.
If Tamper Recognition (see page 30) is disabled, the control panel will not report the occurrence of any
tampers, wire faults or tamper restores.
9.2.10
S
YSTEM
T
ROUBLE
R
EPORT
C
ODES
Section [205] to [207]
Whenever the system generates one of the instances listed below, the control panel can send the appropriate report
code to the central station identifying the type of system trouble.
Section [205]
•
Future use
•
AC F
AILURE
: The control panel has detected a loss of AC power. Transmission of this report code can be delayed
(see Power Failure Report Delay on page 38).
•
B
ATTERY
F
AILURE
: backup battery is disconnected or battery voltage is
≤
10.5V.
•
A
UXILIARY
S
UPPLY
: Auxiliary power supply has overloaded (current consumption is >1.1A).
Section [206]
•
B
ELL
O
UTPUT
O
VERLOAD
: Bell/siren output has overloaded (see page 8).
•
B
ELL
O
UTPUT
D
ISCONNECTED
: Devices connected to the Bell Output have been disconnected.
•
T
IMER
L
OSS
: The control panel has detected a loss in time or clock failure (see page 41)
•
F
IRE
L
OOP
T
ROUBLE
: The control panel has detected a tamper trouble on a fire zone.
Section [207]
•
W
IRELESS
L
OW
B
ATTERY
: The battery voltage of an Omnia wireless transmitter (motion detector or contact switch)
has dropped below recommended limits.
•
M
ODULE
F
AULT
: Will report if all keypads connected to the control panel have been disconnected or if a module with
its corresponding supervision option enabled in the control panel (see pages 43 and 44) is disconnected.
•
P
RINTER
F
AULT
: An error has occurred on the Printer Module.
•
F
AIL
T
O
C
OMMUNICATE
: The control panel has failed all attempts to communicate with the central station. The report
code will be transmitted upon the next successful attempt.