![Paradox Spectra 1759EX V1.0 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/paradox/spectra-1759ex-v1-0/spectra-1759ex-v1-0_reference-and-installation-manual_3630036030.webp)
28
R
EFERENCE
& I
NSTALLATION
M
ANUAL
7.6.1
A
UTO
-A
RM
T
IMER
Section [111] = Partition 1, [112] = Partition 2
Select the section corresponding to the desired partition and program the time (use the 24-hour clock i.e. 6:30PM =
18:30) that you wish the control panel to attempt to arm the selected partition and/or send the Late to Close report
code. If Timed Auto-Arming is disabled, the control panel will still send the Late to Close report code at the time
specified by the Auto-Arm Timer.
7.7
NO MOVEMENT AUTO-ARMING
Section [133] = Partition 1, [134] = Partition 2
Option
[2]
OFF = No Movement Auto-Arming Disabled (default)
Option
[2]
ON = No Movement Auto-Arming Enabled
If no movement occurs in a partition's protected area for the period specified by the No Movement Timer (see below), the control
panel can automatically arm that partition. The Auto-Arming Option described in section 7.8 of this manual determines the
partition's arming method. Any open zones detected when a partition is Auto-Armed will be bypassed regardless of their definition
(except 24hr. zones). Upon arming, the control panel will transmit the No Movement report code if programmed in section [172].
Regardless of whether the system was successfully armed or not, the control panel will always transmit the No Movement report
code if programmed in section [172]. If No Movement Auto-Arming is disabled, the control panel will still send the No Movement
report code at the time specified by the No Movement Timer.
Example: To arm partition 1 whenever there is no movement for a period of 4 hours, enable No Movement Auto-arming for
partition 1 by turning on the [2] Option in section [133]. Then in section [075] enter 016 (16x15min. = 240min. = 4 hours).
7.7.1
N
O
M
OVEMENT
T
IMER
Section [075] = Partition 1, [076] = Partition 2
001 to 255 x15min., Default = disabled
Select the section corresponding to the desired partition and program the interval of time without movement you wish
the control panel to wait before arming and/or sending the No Movement report code. If No Movement Auto-Arming is
disabled, the control panel can still send the No Movement report code when no movement has been detected for the
period specified by the No Movement Timer.
7.8
AUTO-ARMING OPTIONS
(NOT TO BE USED WITH UL INSTALLATIONS)
Section [133] = Partition 1, [134] = Partition 2
Option
[3]
OFF = Regular Arming (default)
Option
[3]
ON = Stay Arming
When using Timed Auto-Arming or No Movement Auto-Arming (see section 7.6 and section 7.7), the control panel can Regular or
Stay Arm (see page 48) the selected partition.
7.9
ONE-TOUCH ARMING
(NOT TO BE USED WITH UL INSTALLATIONS)
Section [130]: Options [1] to [4]
Option
[1]
ON = Press & hold the
[
ENTER
]
key for One-touch Regular Arming.
Option
[2]
ON = Press & hold the
[
STAY
]
key for One-touch Stay Arming.
Option
[3]
ON = Press & hold the
[
FORCE
]
key for One-touch Force Arming.
Option
[4]
ON = Press & hold the
[
BYP
]
key for One-touch Bypass Programming.
The One-touch Arming features allow users to arm the system without having to enter any access codes. To arm the system,
press and hold the appropriate key (see above) for approximately 2 seconds. If the system is partitioned (see page 41), you must
also press the key corresponding to the partition you wish to arm. For more information on the different arming methods, please
refer to page 48.
7.10
EXIT DELAY
Section [071] = Partition 1, [072] = Partition 2
001 to 255 seconds, Default = 30 seconds,
Maximum 60 seconds for UL Listed systems
After entering the required arming sequence (i.e. User Access code, etc.), the Exit Delay parameter determines the amount of
time a user has to leave the protected area before the control panel arms the partition. The Exit Delay applies to all zones in the
selected partition. When enabled, the keypad will beep once every second during the Exit Delay and will beep rapidly during the
final 10 seconds of the Exit Delay.
7.10.1
B
EEP
O
N
E
XIT
D
ELAY
Section [130]: Arming/Disarming Options
Option
[8]
OFF = Beep on Exit Delay Disabled
Option
[8]
ON = Beep on Exit Delay Enabled (default)
Содержание Spectra 1759EX V1.0
Страница 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 1759EX...
Страница 2: ......
Страница 59: ......