![Paradox Spectra 1759EX V1.0 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/paradox/spectra-1759ex-v1-0/spectra-1759ex-v1-0_reference-and-installation-manual_3630036037.webp)
S
PECTRA
1759EX
35
9.2.11
S
YSTEM
T
ROUBLE
R
ESTORE
C
ODES
Sections [208] to [210]
Whenever the system restores one of the troubles listed in section 9.2.10, the control panel can send the appropriate
report code to the central station identifying the type of system trouble restore. If Telephone Line Monitoring is enabled
(see page 38), the control panel can also transmit a TLM Restore report code.
9.2.12
S
PECIAL
R
EPORTING
C
ODES
Sections [211] to [213]
Whenever the system generates one of the instances listed below, the control panel can send the appropriate report
code to the central station identifying the type of system occurrence.
Section [211]
•
C
OLD
S
TART
: The control panel was completely shutdown (no battery, no AC) and then was re-started.
•
T
EST
R
EPORT
: A test report has been generated automatically (see page 38).
•
Not available
•
P
C
E
XIT
: The control panel has ended communication with WinLoad.
Section [212]
•
I
NSTALLER
I
N
: Installer has entered the programming mode.
•
I
NSTALLER
O
UT
: Installer has exited the programming mode.
•
Future use
•
Future use
Section [213]
•
T
X
S
UPERVISION
L
OSS
: Wireless Transmitter Supervision (see SPC-319 Instruction Sheet) has been enabled and a
transmitter is no longer communicating with the system.
•
T
X
S
UPERVISION
R
ESTORE
: Reports when the above trouble has been restored
•
Future use
•
Future use
9.3
CENTRAL STATION TELEPHONE NUMBERS
Section [151] = Phone#1, [152] = Phone#2, [153] = Backup Phone#: Up to 32 digits
The Spectra Control Panels can dial up to 2 different central station telephone numbers. You can enter any digit from 0 to 9 and
any special keys or functions (see Table 9) up to a maximum of 32 digits. For more information on how these telephone numbers
are used, please refer to Event Call Direction on page 37 and Reporting Formats in section 9.5. After the Maximum Dialing
Attempts (see page 37) to one central station telephone number have failed, the control panel will then dial the backup telephone
number. If the Alternate Dial Option (see page 38) is enabled, the control panel will dial the programmed backup telephone
number after every failed attempt. If no backup telephone number is programmed, the control panel will never report to the
backup telephone number. Also refer to Delay Between Dialing Attempts on page 38.
9.4
PARTITION ACCOUNT NUMBERS
Section [143] = Partition 1, [144] = Partition 2
All report codes are preceded by a 4-digit or 3-digit Partition Account Number to ensure correct identification in a partitioned system.
Partition account numbers can be any hexa-digit from 1 to F. To enter a 3-digit account number, simply press the [
FORCE
] key
followed by the 3-digit account number. Also, when using 3-digit account numbers, you must use 1-digit report codes.
9.5
REPORTING FORMATS
Section [140]: 1st digit = Format for Phone #1, 2nd digit = Format for Phone #2
The Spectra Control Panels can use a number of different reporting formats and each Central Station Telephone Number can be
programmed with a different reporting format. The first digit entered into section [140] represents the reporting format used to
communicate with Central Station Telephone Number 1, the second digit represents the reporting format used to communicate with
Central Station Telephone Number 2. The Backup Telephone Number uses the same reporting format as the last Central Station
Telephone Number that was dialed.
Table 9: Special Keys for Telephone Numbers
Press
Action or Value
[
STAY
]
*
[
BYP
]
#
[
MEM
]
switch from pulse to tone dialing or vice versa
[
TBL
] or [
TRBL
]
4-second pause
[
FORCE
]
deletes current digit
[
PG
] or [
FNC
1]
inserts blank space