![Paradox Spectra 1759EX V1.0 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/paradox/spectra-1759ex-v1-0/spectra-1759ex-v1-0_reference-and-installation-manual_3630036029.webp)
S
PECTRA
1759EX
27
PART 7: ARMING AND DISARMING OPTIONS
7.1
SWITCH TO STAY ARMING
Section [133] = Partition 1, Section [134] = Partition 2
Option
[4]
OFF = Switch to Stay Arming Disabled (default)
Option
[4]
ON = Switch to Stay Arming Enabled
If a user Regular arms a partition, but does not exit through (open and close) an Entry Delay zone during the Exit Delay, the
control panel can be programmed to switch from Regular Arming to Stay Arming.
7.2
STAY ARMING WITH DELAY
Section [133] = Partition 1, Section [134] = Partition 2
Option
[5]
OFF = Stay Arming with Delay Disabled (default)
Option
[5]
ON = Stay Arming with Delay Enabled
When a partition is Stay Armed when this feature is enabled, all the zones in the partition, except 24Hr. zones, are associated
with the Stay Delay. Therefore, the control panel will not generate an alarm if a zone is breached until the Stay Delay has elapsed.
This feature prevents false alarms by allowing users enough time to disarm their system if a zone is accidentally triggered. For
example, if a user opens an armed window or crosses an armed detector on the way to the kitchen in the middle of the night, the
user will have enough time to disarm the system before the alarm is generated. Each partition’s Stay Delay follows the value
programmed in Entry Delay Timer 2 in section [070].
7.3
REGULAR ARMING SWITCHES TO FORCE ARMING
(NOT TO BE USED WITH UL INSTALLATIONS)
Section [131]: Arming/Disarming Options
Option
[2]
OFF = Regular Arming Switches to Force Arming Disabled (default)
Option
[2]
ON = Regular Arming Switches to Force Arming Enabled
With this feature enabled, the control panel will always Force arm instead of Regular arm when a valid User Access Code with
the Force Arming Option is entered. In installations where the user must always Force arm when leaving the protected area, this
feature allows users to Force arm without pressing the [
FORCE
] key before entering their User Access Code.
7.4
RESTRICT ARMING ON BATTERY FAIL
Section [130]: Arming/Disarming Options
Option
[5]
OFF = Permit arming on battery failure (default)
Option
[5]
ON = Restrict arming on battery failure
If this option is enabled, the control panel will not arm the system if the control panel detects that the backup battery is
disconnected, that its fuse is blown, or that the battery voltage drops to less than 10.5V. The control panel will not arm the system
until all battery trouble conditions are rectified.
7.5
RESTRICT ARMING ON TAMPER FAILURE
Section [130]: Arming/Disarming Options
Option
[6]
OFF = Permit arming on tamper failure (default)
Option
[6]
ON = Restrict arming on tamper failure
If this option is enabled, the control panel will not arm the system if the control panel detects a tamper trouble on one or more
zones. The control panel will not arm the system until all tamper trouble conditions are rectified.
This feature will not function if the Tamper Recognition Options (see page 30) are disabled or whenever the
tampered zone is bypassed and the Tamper Bypass Options (see page 30) have been enabled.
7.6
TIMED AUTO-ARMING
Section [133] = Partition 1, [134] = Partition 2
Option
[1]
OFF = Timed Auto-Arming Disabled (default)
Option
[1]
ON = Timed Auto-Arming Enabled
Each partition can be programmed to arm every day at the time specified by the Auto-Arm Timer. The Auto-Arming Options (see
section 7.8) determine the partition's arming method. Any open zones detected when a partition is Auto-Armed will be bypassed
regardless of their definition (except 24hr. zones). The control panel will enter a 60-second Exit Delay period before arming the
system. At this point, Auto-Arming can be cancelled by entering a valid access code. Once the partition has successfully armed,
the control panel can transmit the Timed Auto-Arming report code programmed in section [172].
Example: To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-Arming for partition 2 by turning on option [1]
in section [134]. Then key in 18:15 into section [112].
Содержание Spectra 1759EX V1.0
Страница 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 1759EX...
Страница 2: ......
Страница 59: ......