![Paradox Spectra 1759EX V1.0 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/paradox/spectra-1759ex-v1-0/spectra-1759ex-v1-0_reference-and-installation-manual_3630036040.webp)
38
R
EFERENCE
& I
NSTALLATION
M
ANUAL
9.13
DELAY BETWEEN DIALING ATTEMPTS
Section [082]
000 to 255 seconds, Default = 20 seconds
This delay determines the amount of time the control panel will wait between each dialing attempt.
9.14
ALTERNATE DIAL OPTION
Section [136]: Dialer Options
Option
[4]
OFF = Alternate Dial Disabled (default)
Option
[4]
ON = Alternate Dial Enabled
With option [4] OFF, the control panel will dial the backup telephone number programmed in section [153] after all attempts to
one Central Station Telephone Number have failed (see section 9.12). With option [4] ON, the control panel will dial the backup
telephone number after every failed attempt.
9.15
RECENT CLOSE DELAY
Section [085]
000 to 255 seconds, Default = no delay
If after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the control panel will
attempt to transmit the Recent Close report code programmed in section [195].
9.16
AUTO TEST REPORT
Sections [087]
000=disabled, 001 to 255 days, Default = disabled
Section [110]: Time (HH:MM)
The control panel will transmit the Test Report report code programmed into section [211] after the number of days programmed
into section [087] has elapsed at the time programmed into section [110]. Use the 24-hour clock to program the time (i.e. 6:30PM
= 18:30). The first Test Report will be transmitted within 24 hours after the feature is enabled at the time programmed in [110].
Example: Section [087] = 005 and section [110] = 13:00. The first Test Report will be sent at 1 PM that day and then the report
will be sent every 5 days at 1 PM.
9.17
POWER FAILURE REPORT DELAY
Section [086]
001 to 255 minutes, Default = 15 minutes
The control panel will transmit the AC Failure report code programmed in section [205] after the Power Failure Report Delay
period has elapsed.
9.18
DISARM REPORTING OPTIONS
Section [131]: Arming /Disarming Options
Option
[1]
OFF = Always Report Disarming
Option
[1]
ON = Report Disarming Only After Alarm (default)
With option [1] OFF, the control panel will send the Disarming report codes (see page 33) to the central station every time the
system is disarmed. With option [1] ON, the control panel will send the Disarming report codes to the central station when the
system is disarmed following an alarm.
9.19
ZONE RESTORE REPORT OPTIONS
Section [132]: Zone Options
Option
[6]
OFF = Report On Bell Cut-Off (default)
Option
[6]
ON = Report On Zone Closure
With option [6] OFF, the control panel will send the Zone Alarm Restore report codes (see page 34) to the central station when
the zone has returned to normal and the Bell Cut-Off Timer has elapsed (see page 29). With option [6] ON, the control panel will
send the Zone Alarm Restore report codes to the central station as soon as the zone returns to normal or when the system is
disarmed.
9.20
TELEPHONE LINE MONITORING (TLM)
When enabled, the system verifies the existence of a telephone line once every second. A line test failure occurs when the TLM
detects less than 3 volts for the period defined by the TLM Fail Timer. If the line test fails, the control panel’s
STATUS
LED flashes
and generates one or more conditions as defined by the TLM settings below. These will be restored when the control panel
detects the telephone line again. Please note that when the dialer detects an incoming call, the TLM test will stop for 1 minute.
Содержание Spectra 1759EX V1.0
Страница 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 1759EX...
Страница 2: ......
Страница 59: ......