7.11 BELL SQUAWK ON ARM/DISARM WITH KEYPAD
Section [130]: Arming/Disarming Options
Option
[7]
OFF = Bell Squawk on Arm/Disarm Disabled (default)
Option
[7]
ON = Bell Squawk on Arm/Disarm Enabled
When this feature is enabled, the bell or siren will squawk once upon arming and twice upon disarming.
7.12 BELL SQUAWK ON ARM/DISARM WITH REMOTE CONTROL
Section [131]: Arming/Disarming Options
Option
[3]
OFF = Bell Squawk on Arm/Disarm with Remote Control Disabled (default)
Option
[3]
ON = Bell Squawk on Arm/Disarm with Remote Control Enabled
When this feature is enabled, the bell or siren will squawk once upon arming with a remote control and twice upon disarming with
a remote control. Must be enabled for UL installations.
7.13 NO EXIT DELAY WHEN ARMING WITH REMOTE CONTROL
Section [131]: Arming/Disarming Options
Option
[4]
OFF = Provides Exit Delay When Arming with a Remote Control (default)
Option
[4]
ON = No Exit Delay When Arming with a Remote Control
When the option is enabled, the panel cancels the Exit Delay (arms instantly) when a partition is armed with a remote control.
When disabled, the Exit Delay timer will start when a partition is armed with a remote control.
7.14 NO EXIT DELAY BEEPS AND NO BELL SQUAWK WHEN STAY ARMING
Section [131]: Arming/Disarming Options
Option
[5]
OFF = No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled (default)
Option
[5]
ON = No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled
With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from beeping during the
Exit Delay, whenever a partition is Stay Armed.
PART 8: ALARM OPTIONS
8.1
BELL CUT-OFF TIMER
Section [073] = Partition 1, [074] = Partition 2
000 = Disabled, 001 to 255 minutes, Default = 4 minutes,
5 minutes minimum for ULC installations
After an audible alarm, the bell or siren will stop upon disarming of the partition or when the Bell Cut-Off Timer has elapsed,
whichever comes first.
8.2
RECYCLE ALARM
After the Bell Cut-Off Timer and the Recycle Delay have elapsed, the control panel will re-verify the zone status. If there are any
open zones, the control panel will generate another alarm. In one armed period, the control panel will repeat this sequence the
number of times defined by the Recycle Counter.
8.2.1
R
ECYCLE
A
LARM
D
ELAY
Section [090]
000 = disabled, 001 to 255 minutes, Default = disabled
The Recycle Delay determines the amount of time after Bell Cut-Off that the control panel will wait before re-verifying
zone status.
8.2.2
R
ECYCLE
C
OUNTER
Section [091]
000 = disabled, 001 to 255, Default = disabled
The Recycle Counter determines the number of times the control panel will re-verify the zone status after Bell Cut-Off
in one armed period.