Paradox Spectra 1759EX V1.0 Скачать руководство пользователя страница 35

S

PECTRA

 1759EX 

  33

9.1

REPORTING/DIALER (ENABLE/DISABLE)

Section [135]: Dialer Options

Option [3] OFF = Reporting/Dialer Disabled (default)

Option [3] ON = Reporting/Dialer Enabled

9.2

REPORT CODES 

A report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 to F. Each section from [160] to [213] represents a set
of up to four specific events and each of these events can be programmed with a separate 1- or 2-digit report code. 

Only the Ademco Slow, Silent Knight, Sescoa and Pager Formats support 1-digit report codes. To program a 1-
digit report code, press the [

FORCE

] key followed by the desired hexadecimal digit or vice versa. 

When a specific event occurs, the control panel will attempt to transmit the programmed report code to the central station. The
method of report code transmission is defined by the Reporting Formats (see page 35) and the Event Call Direction (see
page 37). These two items define how and where the report codes are transmitted. If you are using the Ademco Contact ID “All
Codes” format, sections [160] to [213] do not have to be programmed. For more information, refer to Reporting Formats (see
page 35). The following sub-sections provide a brief description of the events that the control panel can report.

9.2.1

A

RMING

 R

EPORT

 C

ODES

Sections [160] to [171]

A report code can be programmed for each of the 48 User Access Codes. When using an access code to arm a
partition, the control panel can send the appropriate report code to the central station, identifying which access code
was used to arm the partition.

9.2.2

S

PECIAL

 A

RMING

 R

EPORT

 C

ODES

Sections [172] and [173]

Whenever the system is armed using one of the special arming features listed below, the control panel can send the
appropriate report code to the central station identifying how the system was armed.

Section [172]

T

IMED

 

AUTO

-

ARMING

: A partition has armed itself at the programmed time (see page 27)

L

ATE

 

TO

 C

LOSE

: Reports every day at the time specified by the Auto-Arm Timer (see page 28)

N

O

 M

OVEMENT

: A partition has armed itself after the programmed period without movement (see No Movement 

Arming on page 28).

P

ARTIAL

 A

RMING

: A partition was Stay, Instant or Force Armed or armed with Bypassed zones.

Section [173]

O

NE

-

TOUCH

 A

RMING

: A partition was armed using a One-touch Arming feature (see page 28).

R

EMOTE

 A

RMING

: A partition was armed using the Winload software. 

K

EYSWITCH

 A

RMING

: A partition was armed using a keyswitch (see page 19)

Future use

9.2.3

D

ISARMING

 R

EPORT

 C

ODES

Sections [174] to [185]

A report code can be programmed for each of the 48 User Access Codes. Whenever an access code is used to disarm
an armed partition or a partition in alarm, the control panel can send the appropriate report code to the central station,
identifying which access code was used to disarm the partition. 

The Disarming and the Special Disarming report codes can be transmitted every time a partition is disarmed or
only when a partition is disarmed after an alarm (see Disarming Reporting Options on page 38).

9.2.4

S

PECIAL

 D

ISARMING

 R

EPORT

 C

ODES

Section [186]

Whenever using one of the special disarming features, the control panel can send the report code to the central
station, identifying how the system was disarmed.

C

ANCEL

 A

UTO

-

ARM

: A partition is disarmed during the Timed Auto-Arm's 60-second Exit Delay (see page 27). Only 

reports if Disarming Reporting Options (see page 38) are set to always report disarming. 

R

EMOTE

 D

ISARM

: System is disarmed using   the   Winload software.                                                                                                                        

K

EYSWITCH

 D

ISARMING

: System disarmed using a keyswitch (see page 19).

Future use

9.2.5

Z

ONE

 A

LARM

 R

EPORT

 C

ODES

Sections [187] to [190]

A report code can be programmed for each of the 15 available zones. Whenever a zone generates an alarm, the
control panel can send the appropriate report code to the central station, identifying which zone generated an alarm.

Содержание Spectra 1759EX V1.0

Страница 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 1759EX...

Страница 2: ......

Страница 3: ...tions 28 One Touch Arming 28 Exit Delay 28 Bell Squawk On Arm Disarm With Keypad 29 Bell Squawk On Arm disarm with Remote Control 29 No Exit Delay When Arming with Remote Control 29 No Exit Delay Beep...

Страница 4: ...switch Arming 50 Panic Alarms 50 Auto Arming 51 Alarm Memory Display 51 Programming Chime Zones 51 Keypad Muting 51 Keypad Backlight 1686H and 1686V only 51 FCC WARNINGS 52 INDEX 54 LIST OF TABLES Tra...

Страница 5: ...own Beep on Exit Delay Programmable Delay Before Alarm Transmission and Recent Closing Report Regular Arming Stay Arming Instant Arming Force Arming One Touch Arming Auto Arming or Keyswitch Arming 25...

Страница 6: ...iendly keypad will complete any installation 1 3 3 SPECTRA 1641 LCD KEYPAD The 1641 is a 32 character programmable LCD keypad which includes a zone input as well as a PGM output View zone event and tr...

Страница 7: ...voice dialer take over Compatible with any control panel the Paravox will verbally report system status by phone advising of detection of burglary fire flood or any other situation programmed to gene...

Страница 8: ...e grounded to the cold water pipe 2 3 AC POWER Do not use any switch controlled outlets to power the transformer Connect the transformer as shown in Figure 2 1 on page 6 Use Table 1 to determine the r...

Страница 9: ...ns refer to Configuring The LED Keypads on page 12 Refer to Single Zone Inputs on page 9 Refer to AC Power and Backup Battery Connections on page 6 To connect the 5A Alarm Relay and the PGMs refer to...

Страница 10: ...If the BELL output is not being used the Bell Disconnected failure will remain in the keypads Trouble Display see page 47 To avoid this connect a 1K resistor across the BELL terminals 2 8 PROGRAMMABL...

Страница 11: ...on page 16 Figure 2 4 Single Zone Input Connections 2 10 KEYPAD AND KEYPAD ZONE CONNECTIONS To connect the keypads to the control panel remove the back cover and wire the GRN YEL RED and BLK terminals...

Страница 12: ...minals Once a keyswitch is connected it must be assigned to a zone and its parameters must be programmed see Zone Programming on page 16 and Keyswitch Options on page 21 2 12 FIRE CIRCUITS When a zone...

Страница 13: ...126 to 138 and 302 to 348 each option from 1 to 8 represents a specific feature or option Press the key corresponding to the desired option and the corresponding light will illuminate or the option n...

Страница 14: ...istor be connected refer to Spectra 1759EX Control Panel Overview on page 7 for more details Key 2 OFF EOL disabled Key 2 ON EOL enabled default Key 3 On Board Tamper Key 3 enables or disables the key...

Страница 15: ...ORY KEY Copy the sections of one Spectra control panel into the Paradox Memory Key PMC 3 Then copy the contents of the Memory Key into as many Spectra control panels as needed Each panel is programmed...

Страница 16: ...tions The System Master Code can be 4 or 6 digits in length see section 4 1 where each digit can be any digit from 0 to 9 To change the System Master Code press ENTER INSTALLER CODE 301 new 4 or 6 dig...

Страница 17: ...ming is dependent on the other User Code Options selected Please note that with the Arm Only option the user can cancel a recently armed system by re entering the access code before the end of the Exi...

Страница 18: ...modules to the same expansion input 5 2 REASSIGN KEYPAD ZONE 2 Section 126 General Options Option 7 OFF Reassign Keypad Zone 2 Disabled default Option 7 ON Reassign Keypad Zone 2 Enabled Reassign Key...

Страница 19: ...e s partition assignment and how the control panel will react when an alarm condition occurs on that zone These Zone Parameters are programmed into one section as detailed in Figure 5 1 on page 18 Onl...

Страница 20: ...ition may require a different Entry Delay 5 5 2 ENTRY DELAY 2 Sections 001 to 015 Zones 1 to 15 First Digit 2 Entry Delay 2 zones are identical to the Entry Delay 1 zones see section 5 5 1 except it u...

Страница 21: ...collection 5 6 EXCLUSIVE ZONE DEFINITIONS The following three zone definitions can only be used for devices connected directly to the control panel s on board input terminals When a zone is programmed...

Страница 22: ...ounter the control panel will no longer generate an alarm for that zone To program the Auto Zone Shutdown Counter key in the desired limit 000 Disabled 001 to 015 Default 5 into section 089 The Auto Z...

Страница 23: ...ON Delay Alarm Transmission Enabled for Selected Zone When an alarm condition occurs on a zone with this option enabled the control panel enables the bell siren output but does not report the alarm to...

Страница 24: ...8 represent expansion inputs 1 to 8 respectively For example section 601 is assigned to expansion input 1 section 602 is assigned to expansion input 2 etc refer to Table 6 Each Expansion Input represe...

Страница 25: ...ll advise you of the transmitter s signal strength This feature cannot be used with any remote controls assigned to the control panel 6 3 SERIAL NUMBER DISPLAY Section 630 This feature will display th...

Страница 26: ...to section 6 4 1 on page 24 for instructions on enabling check in supervision Options 2 and 5 must match the jumper settings of the assigned transmitters For example if the check in supervision is se...

Страница 27: ...arm all the areas assigned to the User Access Code see section 6 5 4 on page 25 Sections 711 to 718 represent the remote controls assigned to sections 731 to 738 refer to section 6 5 2 on page 25 For...

Страница 28: ...__ ____ ____ ____ A B C D A B C D A C B D Remote Control 4 715 ____ ____ ____ ____ ____ ____ ____ ____ A B C D A B C D A C B D Remote Control 5 716 ____ ____ ____ ____ ____ ____ ____ ____ A B C D A B...

Страница 29: ...RCE key before entering their User Access Code 7 4 RESTRICT ARMING ON BATTERY FAIL Section 130 Arming Disarming Options Option 5 OFF Permit arming on battery failure default Option 5 ON Restrict armin...

Страница 30: ...e without movement you wish the control panel to wait before arming and or sending the No Movement report code If No Movement Auto Arming is disabled the control panel can still send the No Movement r...

Страница 31: ...Disarming Options Option 5 OFF No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled default Option 5 ON No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled With this feature e...

Страница 32: ...pass definition This means the control panel will ignore any tampers detected on a bypassed zone With option 3 off Tamper Recognition ignores the bypass definition This means the control panel will ge...

Страница 33: ...anic alarm is activated the control panel can ignore the disarm signal from a remote control for a specified period This prevents an aggressor from disarming the system by remote control during a pani...

Страница 34: ...Codes Option 6 ON Call Telephone 2 for Tamper Restore Report Codes Section 138 Option 1 ON Call Telephone 1 for Trouble Restore Report Codes Option 2 ON Call Telephone 2 for Trouble Restore Report Cod...

Страница 35: ...TIMED AUTO ARMING A partition has armed itself at the programmed time see page 27 LATE TO CLOSE Reports every day at the time specified by the Auto Arm Timer see page 28 NO MOVEMENT A partition has a...

Страница 36: ...T CODES Sections 201 to 204 A report code can be programmed for each of the 15 available zones Whenever a tampered zone is restored the control panel can send the appropriate report code to the centra...

Страница 37: ...are used please refer to Event Call Direction on page 37 and Reporting Formats in section 9 5 After the Maximum Dialing Attempts see page 37 to one central station telephone number have failed the co...

Страница 38: ...Report Codes Press the FORCE key to enter a 0 value When using the All Codes format the control panel will automatically generate Contact ID Report Codes for every event in sections 160 to 213 Refer...

Страница 39: ...ult When using Pulse dialing you can select one of two Pulse Ratios Although most European countries use the 1 2 pulse ratio the 1 1 5 ratio may provide better results in some cases The same applies f...

Страница 40: ...ys at 1 PM 9 17 POWER FAILURE REPORT DELAY Section 086 001 to 255 minutes Default 15 minutes The control panel will transmit the AC Failure report code programmed in section 205 after the Power Failur...

Страница 41: ...round therefore cutting power to any devices connected to it PGM1 A programmable output that provides up to 150mA Refer to Alarm Relay and PGMs on page 8 PGM2 PGM2 is a programmable output that can pr...

Страница 42: ...PGM output to be normally open N O or normally closed N C by enabling or disabling options 4 5 and 6 in section 126 Option 4 OFF PGM1 Normally Closed Default Option 4 ON PGM1 Normally Open Option 5 OF...

Страница 43: ...Charge Current 350mA default Option 5 ON Battery Charge Current 700mA 40VA transformer required 11 5 PARTITIONING Section 127 General Options Option 1 OFF Partitioning Disabled default Option 1 ON Pa...

Страница 44: ...will send the Zone Tamper report code as originating from partition 1 A Tamper Zone Wiring Failure will also appear in the keypads Trouble Display see page 47 When Reassign Keypad Zone 2 is enabled s...

Страница 45: ...ith the APR prefix are compatible with Spectra versions 2 0 and higher and Digiplex Modules with the APR3 prefix are compatible with Spectra versions 2 0 and higher Digiplex and DigiplexNE 11 13 PRINT...

Страница 46: ...el will follow the zone s Alarm Types setting see page 20 7 ON 8 ON Audible Alarm When a tamper occurs on an Omnia wireless transmitter zone in a disarmed system it functions the same as the Trouble O...

Страница 47: ...control panel will answer the call You must wait at least 10 seconds before attempting the second call or the control panel will think it is the same call 12 2 PANEL IDENTIFIER Section 141 0000 to FF...

Страница 48: ...communication is interrupted before completing transmission or if after two attempts communication is not established the system will wait until the Event Buffer attains another 50 capacity before att...

Страница 49: ...elay in section 086 The AC LED turns back on as soon as power is restored 4 Bell Disconnected This trouble occurs when a bell or siren is not connected to the bell output terminals If you are not usin...

Страница 50: ...ed partition If you make a mistake the FORCE or 16 Keypad Fault If the keypad is no longer communicating with the control panel the TBL or TRBL will flash the FORCE key will illuminate the LCD keypad...

Страница 51: ...Any open Force Zones at the time of arming will be considered deactivated by the control panel If during this period a deactivated zone is closed the control panel will revert that zone to active sta...

Страница 52: ...t Delay At the end of the Exit Delay period the control panel will switch to Force Arming 13 10 KEYSWITCH ARMING A keyswitch can be used to arm and disarm the system Assign the keyswitch to a specific...

Страница 53: ...ep this means the chime feature has been enabled for that zone If the keypad emits a rejection beep this means the chime feature has been disabled for the corresponding zone 16 ZONE LED KEYPAD Press a...

Страница 54: ...t installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installat...

Страница 55: ...ces de charge de l ensemble des dispositifs ne d passe pas 100 La certification d Industrie Canada s applique seulement aux installations d appareils utilisant un transformateur approuv par l Associat...

Страница 56: ...awk On Arm disarm with Remote Control 29 Burglary Zones 24 Hr 19 Buzzer Zone 19 Bypass Options Supervision 44 Bypass Programming 49 Bypass Recall Feature 50 Bypass Zones 20 C Call Back Feature 46 Call...

Страница 57: ...back Upon Stay Arming 29 No Exit Delay When Arming with Remote Control 29 No Movement Auto Arming 28 Number of Rings 45 O One Touch Arming 28 50 Options Alarm 29 Arming and Disarming 27 Auto Arming 28...

Страница 58: ...hone Number PC 45 Telephone Numbers 35 Test Report Automatic 38 Test Report Manual 43 Timed Auto Arming 27 Transformer Requirements 6 Trouble Display 47 U Upload Download Software 11 User Code Options...

Страница 59: ......

Страница 60: ...780 boul Industriel St Eustache Montr al Qu bec J7R 5V3 Fax 450 491 2313 www paradox ca PRINTED IN CANADA 02 2002 1759EX EI00...

Отзывы: