11.15 WIRELESS TRANSMITTER LOW BATTERY SUPERVISION
Section [129]: General Options
Option [6] OFF
= Wireless Transmitter Low Battery Supervision Disabled (default)
Option [6] ON
= Wireless Transmitter Low Battery Supervision Enabled
When option [6] in section [129] is enabled and the battery voltage of an Omnia wireless transmitter (motion detector or contact
switch) has dropped below recommended limits, the control panel will attempt to transmit the Wireless Transmitter Low Battery
report code programmed in section [210] and the Wireless Transmitter Low Battery Failure will appear in the keypads’ Trouble
Display (see page 47).
11.16 WIRELESS TRANSMITTER SUPERVISION OPTIONS
Section [132]: Zone Options
[7] OFF / [8] OFF: Supervision Failure Recognition Disabled (default)
When a tamper occurs on an Omnia wireless transmitter zone in a disarmed system, the control panel will display the zone as
open in the keypad display, but will not generate an alarm. When it occurs on in an armed system, the control panel will follow
the zone's Alarm Types setting (see page 20). This option is not permitted on UL systems.
[7] OFF / [8] ON: Trouble Only
When a tamper occurs on an Omnia wireless transmitter zone in a disarmed system, a Wireless Transmitter Supervision Loss
will appear in the keypads’ Trouble Display (see page 47) and the control panel will attempt to transmit the TX Supervision Loss
report code programmed in section [213]. When it occurs on in an armed system, the control panel will follow the zone's Alarm
Types setting (see page 20).
[7] ON / [8] OFF: Silent Alarm
When a tamper occurs on an Omnia wireless transmitter zone in a disarmed system, it functions the same as the Trouble Only
setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens, but the system will have to be
disarmed. In an armed system, the control panel will follow the zone's Alarm Types setting (see page 20).
[7] ON / [8] ON: Audible Alarm
When a tamper occurs on an Omnia wireless transmitter zone in a disarmed system, it functions the same as the Trouble Only
setting, except it will also generate an audible alarm. In an armed system, the control panel will follow the zone's Alarm Types
setting (see page 20).
11.16.1 R
ESTRICT
A
RMING
ON
S
UPERVISION
L
OSS
Section [131]: Arming/Disarming Options
Option
[6]
OFF = Disabled (default)
Option
[6]
ON = Restrict Arming on Wireless Transmitter Supervision Loss
The control panel will not allow users to arm the system if it receives a Supervision Loss signal. Please note that the
Wireless Transmitter Supervision Options (see section 11.16) must be enabled. The control panel will not arm any
partition until all Supervision Loss trouble conditions are rectified.
11.16.2 S
UPERVISION
B
YPASS
O
PTIONS
Section [131]: Arming/Disarming Options
Option
[7]
OFF = Generate Supervision Loss if detected on a Bypassed Wireless Transmitter Zone
(default)
Option
[7]
ON = No Supervision Loss if Detected on a Bypassed Wireless Transmitter Zone
When this feature is enabled, the Wireless Transmitter Supervision Options will follow the zone's bypass definition.
This means the control panel will not perform any action if a Supervision Loss occurs on a bypassed zone. When this
feature is disabled, the Wireless Transmitter Supervision Options will ignore the bypass definition. This means the
control panel will generate an incident as per Wireless Transmitter Supervision Options if a supervision loss occurs on
a bypassed zone.
11.17 REPROGRAM ALL EXPANSION MODULES
Section [750]
After removing an expansion bus module from the communication bus, the control panel keeps the module’s programmed
sections in memory. Therefore, if you add or replace a module or when you have downloaded the contents of the Paradox
Memory Key (see section 3.4), you can reprogram the modules with the settings saved in the control panel. To do so, enter
section [750] and press [
ENTER
]. The keypad will emit 2 beeps every second while downloading.