P300H
P300 Series Modem Installation and Operating Handbook
Page 23
4
SUMMARY OF SPECIFICATIONS
Common Main Specifications
Optional features are shown in
[square brackets]
Modulation
BPSK, QPSK, OQPSK, [8PSK]
Frequency/Resolution
P300: 50 MHz - 90 MHz, 100Hz resolution.
[50 MHz - 180 MHz Wideband IF feature]
P310: 950MHz - 1750MHz 100Hz resolution
[950 MHz - 2150 MHz Wideband IF feature]
Traffic Interface
Electrical
RS422, V.35 and RS232 software selectable (clocking can provide
X.21 DCE or DTE mode)
Mechanical
Both EIA530 DCE and RS449 DCE connectors (25 pin and 37 pin `D`
female respectively).
Options
T1 or E1 G.703
in addition
to RS422, V.35, & RS232 (software
selectable)
For special requirements a customer specific interface card may be
fitted.
User Data Rates
Closed Network
Resolution of 1 bps
Rate
Rate
Rate
Uncoded
Rate
BPSK
min
4.8k
7.2k
8.4k
9.6k
max *
1250k
1875k
2187k
2500k
QPSK / OQPSK
min
9.6k
14.4k
16.8k
19.2k
max *
2.5M
3.75M
4.375M
5.0M
8PSK/TURBO
min
21.6k
25.2k
max *
5.0M
5.0M
8PSK/TCM
min
19.2k
max *
5.0M
[Closed Net plus ESC]
As Closed Net above but limits include an overhead of approx 1.4 x ESC
Baud rate. Resolution of 1 bps. ESC from 50Baud to 38.4kBaud
[IBS/SMS Mode]
<9.6k to >2048k
*
(6.7% overhead added)
Resolution of 1 bps
[IDR Mode]
<64k to >2048k
*
(96k overhead added)
Resolution of 8k (limitation of frame structure)
Note: Maximum data rate is 512kbps in all modes before overheads unless the High Data Rate option is fitted.