1.2 SAFETY
To ensure operator safety the P300 Modems have been designed to comply with the following safety
standard:
EN 60950 Safety of Information Technology Equipment, including electrical business machines.
Prior to installation and operation, please ensure that the following points are observed:
Environmental
The equipment is designed to operate in a static 19-inch rack system conforming to IEC 297-2.
Operation of the equipment in transportable installations and vehicles equipped with the means of
providing a stable environment is permissible. Operation of the equipment on vehicles, ships or aircraft
without means of environmental conditioning may invalidate the safety compliancy. Please contact the
factory for further advice. Operation of the equipment in an environment other than that stated in the
specifications will also invalidate the safety compliancy.
The equipment must not be operated in an environment in which the unit is exposed to:
* Un-pressurised altitudes greater than 2000 metres
* Extremes of temperature outside the stated operating range
* Excessive dust
* Moisture or humid atmospheres above 95% RH
* Excessive vibration
* Flammable gases
* Corrosive or explosive atmospheres
Installation
The equipment is classified in EN 60950 as a pluggable equipment class A for connection to the mains
supply. As such it is provided with a mains inlet cord suitable for use in the country of operation. In
normal circumstances this will be of an adequate length for installation in the rack. If the mains cable
proves to be too short then any replacement must have a similar type fuse (if fitted) and be
manufactured to a similar specification. For example, look for HAR, BASEC or HOXXX-X ratings on the
cable and the connector ends marked with BS1636A (UK free plug 13 amp); BSI, VDE, NF-USE, UL,
CSA, OVE, CEBEC, NEMKO, DEMKO, SETI, IMQ, SEV and KEMA-KEUR for the IEC 6 amp free
socket. Schuko and North American free plugs must have similar markings.
The installation of the equipment and the connection to the mains supply must be made in compliance to
local or national wiring regulations for a category II impulse over-voltage installation. The positioning of
the equipment must be such that the mains supply socket outlet for the equipment should be near the
equipment and easily accessible or that there should be another suitable means of disconnection from
the mains supply.
The equipment is designed to operate from a TN type power supply system as specified in EN 60950.
This means a system that has separate earth, line and neutral conductors. The equipment is
not
designed to operate with an IT power system which has no direct connection to earth.
CAUTION:
This unit has DOUBLE POLE / NEUTRAL FUSING.