6.9.2
Change, Rem-M&C, CONFIGURE Menu
Remote M&C: 1:Protocol [Paradise]
2:Intfc [RS485] 3:Baud rate[2400] 4:Addr[123]
Change, Rem-M&C, Configure Menu
This menu configures the remote M&C port: The options are:
ÐÎÑÌÑÝÑÔ
This allows selection between
ÑÚÚ
,
ÐßÎßÜ×ÍÛñÚÜÝ
, and
Íßó¾«-
. Full details
of the remote M&C protocols and messages is provided in the Remote M&C
section in Appendix D.
NOTE: Remote
monitoring
is possible with the selected protocol if the protocol
is not set to
ÑÚÚ
. Remote
control
is only possible if the protocol is not
Ѻº
and
control has been selected as
λ³±¬»
on the Change, Remote M&C menu.
×ÒÌÛÎÚßÝÛ
The options available here are RS232 or RS485. RS232 is only usable for a
direct connection between a single device and a PC. RS485 is required when
more than one slave device is connected to the remote M&C bus. Again see
the Remote M&C section for complete details of the electrical interface.
ÞßËÜ ÎßÌÛ
The remote M&C Baud Rate is selectable, again see the Remote M&C section
for complete details of suitable Baud Rates for each protocol.
ßÜÜÎÛÍÍ
The bus address must be specified. The valid range for the Paradise / FDC
protocol is 1-255, for the SA-bus protocol the valid range of address is 49 to
111 (31H to 6FH).