P300H
P300 Series Modem Installation and Operating Handbook
Page 93
If the external 10MHz reference fails totally then it will be automatically replaced with the internal
reference. If however it degrades (level, frequency or phase noise),
then until it fails totally the
modem will continue to use it as the synthesiser reference
.
6.7.5
Change, Rx, Buffer / Clocking, RX CLOCK Menu
This screen varies depending on the configuration of the Rx path
Normal (non-Insert Mux operation)
This selects the source of the clock, which feeds the terrestrial output:
Rx output clock: [?]
1=Sat 2=Tx 3=Internal 4=Station 5=DCE
Change, Rx, Buffer / Clocking, Rx Clock (non-Insert) Menu
Insert Mux operation (generated bearer)
This selects the source of the clock for the
PCM BEARER
onto which the Rx data is inserted:
Rx output bearer clock source: [?]
1=Sat 2=Tx 3=Internal 4=Station
Change, Rx, Buffer / Clocking, Rx Clock (Insert-Loop) Menu
Insert Mux operation (looped bearer)
This selects the source of the clock for the
BACKUP
PCM BEARER
, which is only used if the normal
bearer looped from the Drop Mux fails and the unit auto generates a backup bearer onto which to insert
the Rx data. Note that this screen does not display a
̨
option, as it is the
failure
of the Tx bearer input
which causes this backup clock to be used in the first place.
Rx o/p bearer backup clk : [?]
1=Sat 2=Internal 3=Station
Change, Rx, Buffer / Clocking, Rx Clock (Insert-Loop) Menu
All the options available on any of these menus for the
Rx output clock
are as follows:
ÍßÌÛÔÔ×ÌÛ
The clock from the satellite. This provides `Buffer Disable` operation, the buffer
size is set to zero and the buffer size menu is no longer available. This is the
same as `Rx=Rx` clock options found on some other equipment. The Rx PLL
converts the satellite clock, which may include framing and or Reed-Solomon
overheads back to the rate required at the terrestrial port. If the demodulator
cannot lock onto a carrier (ie no clock from satellite), then the PLL switches to
the internal frequency reference to provide a steady clock towards the
terrestrial port.
ÌÈ ÝÔÕ ×Ò
The Tx path input clock is turned around to drive the Rx data back to the
terrestrial. This is normal `Plesiochronous Mode`, and the buffer should be set
large enough to accommodate both the difference in the clocks at each end of
the link PLUS the Doppler shift, whilst providing the required interval between
slips.