Sw1
position 2
1:1 Operation
, the G.703 output goes high impedance if power is
Q323 G.703 (Special) option PCB
SW3-3
TS16 modified
TS16 transparent
1 2 3 4
Mode
Description
removed allowing the units 1:1 partner to carry the traffic. The normal
input impedance switches to whichever one is on-line (with the standby
input at high impedance)
Installation note
: If installing the G.703 card, the BNC labelled `IN` connects to J3 on the card, and the
BNC labelled `OUT` to J2 on the card.
The Q323 is a modified version of Q302 G703 card. The "Q302" switches are
configured as normal. (Please see P300 Installation and Operating handbook)
The additional logic allows the E1 frame data to be modified to solve interaction problems with AIS
data.
The logic does not support modified T1 data.
If the switches are all off, then the data path is just delayed by one bit in both directions.
The new functions are controlled by SW3 on the PCB.
Option
OFF
ON
SW3-1
Normal Operation
TS1-31 Modified
SW3-2
TS0 transparent
TS0 Bit 1 overwritten with CRC4
SW3-4
TS1-31data inversion TS1-31 bit mask inversion
SW3-3 and SW3-4 have no effect if SW3-1 is OFF.
The card supports the following modes.
SW3:
0 0 0 0
Transparent
Card functions as standard Q302
0 1 0 0
Trans CRC4
As above with CRC4 multi-frame in TS0 bit 1
1 0 0 0
TS1-31 Invert
Data through the modem is inverted
1 1 0 0
TS1-31 CRC4
As above with CRC4 multi-frame in TS0 bit 1
1 0 0 1
TS1-31 Bit Invert
Data bits 1, 2, 5 and 6 are inverted
1 1 0 1
TS1-31 Bit CRC4
As above with CRC4 multi-frame in TS0 bit 1
1 0 1 0
TS1-15, 17-31 Invert
Data through the modem is invertedTS16 -
Channel Associated Signaling support
1 1 1 0
TS1-31 CRC4
As above with CRC4 multi-frame in TS0 bit 1
1 0 1 1
TS1-15, 17-31 Bit Invert
Data bits 1, 2, 5 and 6 are inverted TS16 -
Channel Associated Signaling support
1 1 1 1
TS1-15, 17-31 CRC4 As above with CRC4 multi-frame in TS0 bit 1
1 = switch on, 0 = switch off
When transparent TS16 options are selected and the P300 is in drop and inset
mode, the P300 modem must be set to maintain timeslot identities if TS16 is part of