Function parameters in the above table will be described in detail as bellow. Depending
on the load in use and operation state of the motor to set these parameters.
P001
:
1
st
acceleration time
Used to set the time to accelerate to the maximum output frequency from 0.5Hz.
Max. output
frequency
・
The display code for 0.04s is "000".
・
The maximum output frequency is set with parameters
P005 and P008.
Output
frequency(Hz)
0.5
Acceleration
time
0.1(0.1
~
999.9), 1(1000
~
3600)
Setting unit (s)
0.04
・
0.1
~
3600
Data setting range (s)
P002
:
1
st
deceleration time
Used to set the time to decelerate to the maximum output frequency from 0.5Hz.
・
The display code for 0.04s is "000".
・
The maximum output frequency is set with parameters
P005 and P008.
0.1(0.1
~
999.9), 1(1000
~
3600)
Setting unit (s)
0.04
・
0.1
~
3600
Data setting range (s)
Output
frequency
(Hz)
Max. output frequency
0.5
Deceleration
time
Note
・
Take note that if acceleration time is set to a too short value, overcurrent may flow
due to different load states.
Note
・
Take note that if deceleration time is set to a too short value, overcurrent may flow
due to different load states.
62
9-3 Functional Descriptions (By Parameters)
P005, P008
Related
parameters
P005, P008
Related
parameters