11-4. Check function of parameters
[Continued from previous page]
Press the MODE button and enter the operation
preparation completed state.
MODE
Operation preparation
completed state
・・・
The normal stop state will be entered and the inverter can be run.
(Operation status display mode)
Note
・
When the download ends, built-in memory parameter data and parameters of the main unit
are the same.
・
If a run signal enters during downloading, the operation will not be activated. After the operation
preparation completed state is returned to, OP trip will occur.
・
While downloading the data, the set data will be written in non-volatile memory inside the inverter
and the data will be stored even if the power is turned off. Max. writing times of the non-volatile
inside the inverter is 100,000 times. Take note of the downloading times.
・
The function cannot be used during operation. Always use this function in the stopped state.
Used to compare and verify the setting values of function parameters of the main unit and the
setting values of built-in memory parameters inside the connected operation panel. After data
value is set to "VEr", comparison and verification will be activated.
■
Check method of parameters
Press the STOP button to stop the inverter.
Press the MODE button.
Press the MODE button.
Press the MODE button.
Press the MODE button.
(If a password is set, it's necessary to input
the password. Refer to page 139.)
[Continued to next page]
150
MODE
MODE
MODE
MODE
STOP