n005
:
Setting frequency
Indicates the setting frequency of the inverter.
n006
:
Communication station No.
Indicates the set communication station No..
Communication station No. can be set with P136: communication station No. setting.
n007
:
Timer runtimes
In timer's multi speed operation, timer's acceleration and deceleration linking operation,
pulse input multi speed operation and pulse input acceleration and deceleration linking
operation, runtimes in a cycle during each operation are displayed. When a cycle starts,
runtimes will be counted up. When each operation ends, input the next run command,
the counted numbers will be cleared.
Timer runtimes can be set with P068: timer runtimes.
n008
:
Alarm type
Indicates the lighting details of the alarm LED.
* Alarm LED operation select (parameter P147) set to "1"
When various alarms occur simultaneously, the displayed order of priority is shown
as follow. (If alarm in higher priority order is in operation, even an alarm in lower priority
order enters, the alarm in higher priority order is still displayed.)
Output voltage trouble
alarm
Without error
Timer end-of-run signal
Temperature anomaly
alarm
Overload alarm
Display
Alarm state
Temperature
anomaly
alarm
Overload
alarm
Output voltage
trouble alarm
Timer
end-of-run signal
>
>
>
47