Caution
!
Note
●
Always close the terminal cover before turning the input power ON.
Do not open the terminal cover while the power is ON.
Failure to do so could lead to electric shock or fires.
●
Do not operate the switches or dials with wet hands.
Failure to do so could lead to electric shock.
●
Do not touch the inverter terminals when the inverter power is ON or
even when the inverter is stopped.
Failure to do so could lead to electric shock.
●
The STOP button is not designed for emergency stop purposes.
Prepare a separate emergency stop button.
Failure to do so could lead to injury.
●
The heat sink fins and brake resistor can reach high temperatures,
so do not touch them.
Failure to do so could lead to burns.
●
The inverter can be easily set to run from low speeds to high speeds.
Confirm the tolerable range of the motor and machine before starting
operation.
Failure to do so could lead to injury.
●
Prepare holding brakes if required.
Failure to do so could lead to injury.
●
Before turning power ON, check the following points again.
①
Check that all wiring is correct.
Reversed wiring between the power supply and the load, in particular,
can result in damage to the inverter.
②
Make sure the inverter rating and power supply voltages match each other.
③
Make sure no power factor capacitor is connected to the motor,
as it can damage the inverter and the capacitor.
④
Before starting a trial run, check the set frequency.
26
7. Operation (Basic Operation)