33
Stopping operation
Press the STOP button.
The motor will start to decelerate
and will stop.
Stop command
Press the RUN button.
The motor will gradually
decelerate, and will start
reverse run at 25Hz again.
Reverse
Forward
Run command
[Continued from previous page]
[Example for canceling the rotation direction setting]
After setting with the UP and DOWN buttons, the rotation direction can be canceled by
pressing the same button again.
Forward run operation at 25.0Hz
Press the DOWN button and set
the rotation direction to reverse
run.
Reverse
run setting
During forward run operation at 25.0Hz
During operation
Press the DOWN button.
Display will change from the rotation
direction display to operation status
display, and the rotation direction
setting will be canceled.
Canceling setting
Note
・
The setting can be canceled with the same procedure even when stopped.
・
If the RUN button is not pressed after setting the rotation direction, the rotation direction
will not change.
RUN
STOP