②
Rotation direction setting mode method (Parameter P003 set to "0")
In "operation status display mode", press the MODE button twice to enter the "rotation direction
setting mode". Press the SET button to display the rotation direction data, change the rotation
direction with the UP button and DOWN button, and then press the SET button to enter the data.
(Forward run is set as the factory setting.)
Operation will start when the RUN button is pressed.
Monitor function and
direction setting function
○
(Can be used)
Rotation direction setting
mode method
Only monitor function
×
( Cannot be used)
Forward run/reverse run method
Details of rotation
direction setting mode
MOP function
Operating method
* Combination of "Operating method",
"MOP function" and "rotation direction setting mode".
Note
・
When operating method is set to "forward run/ reverse run method", even if the
frequency is set with the "digital setting method", the MOP function cannot be used.
Run
command
status
Forward
/reverse
C
communication
E
External control
operation
L
Operation panel
Display
Run
command
r
Reverse run
F
Forward run
Display
Rotation
direction
Current
state
Forward
/reverse
r
During reverse
run operation
F
During forward
run operation
0
During stop
Display
Current state
r
Reverse run
F
Forward run
Display
Rotation
direction
7-3. Operating With the Operation Panel
Operation 4
Operation 2
Setting value "1"
Operation 3
Operation 1
Setting value "0"
Parameter P003:
Run command select
Setting value "1"
Setting value "0"
Parameter P004: Frequency signal setting
When operating with the operation panel, there are 4 modes constituted by the combination of parameter
P003: run command select and parameter P004: frequency signal setting, as shown in 7-1 Setting
the frequency with the operation panel and 7-2 Setting forward run/ reverse run operation with the
operation panel.
The four operations will be taken as an example to make descriptions in this section.
28