1-16
1
1
1
2
3
4
5
6
7
8
Unit: mm
Mounting hole (4-R6.5),
anchor bolt : M10
Refrigerant tubing (liquid tube),
flared connection (ø9.52)
Refrigerant tubing (gas tube),
flared connection (ø19.05) *1
Refrigerant tubing port
Electrical wiring port (ø13)
Electrical wiring port (ø22)
Electrical wiring port (ø27)
Electrical wiring port (ø35)
29
1500
980
35
60
30
36
82
48
39
121
469
Z VIEW
370
60
60
89
35
82
48
39
121
4
5
6 7 8
5
6
7
8
4
A VIEW
62.5
50
47.5
75.5
16
13
20
412.5
350
160
200
230
160
660
160
(10)
170
370
36
980
4×
ȭ
32 holes (holes for drain)
330
1
A
Air-discharge
Air intake
Air intake
7
5
6
4
8
Z VIEW
42
74
100
120
173
16
51
35
47
Air-discharge
Air intake
When using a drain pipe, install the drain socket
(field supply) onto the drain port. Seal the other
drain port with the rubber cap.
43
2
3
Air intake
(B) Outdoor Unit: U-200PE2E8A
Specifi cation for pipe connecting indoor unit to outdoor unit.
U-200PE2E8A
Model name
Piping
Connections
2
5
.
9
ø
e
d
i
s
d
i
u
q
i
L
25.4
ø
e
d
i
s
s
a
G
(Gas piping connection) While the main gas side pipe is ø25.4,
since connecting the outdoor unit's 3-way valve requires a ø19.05
flare, please be sure to use standard accessories joint piping B or
A for connection (brazing), and connect as follows.
*
1
1
2
3
4
5
6
7
8
Unit: mm
Mounting hole (4-R6.5),
anchor bolt : M10
Refrigerant tubing (liquid tube),
flared connection (ø12.7)
Refrigerant tubing (gas tube),
flared connection (ø19.05)*
1
Refrigerant tubing port
Electrical wiring port (ø13)
Electrical wiring port (ø22)
Electrical wiring port (ø27)
Electrical wiring port (ø35)
29
1500
980
35
60
30
36
82
48
39
121
469
Z VIEW
370
60
60
89
35
82
48
39
121
4
5
6 7 8
5
6
7
8
4
A VIEW
62.5
50
47.5
75.5
16
13
20
412.5
350
160
200
230
160
660
160
(10)
170
370
36
980
4×
ȭ
32 holes (holes for drain)
330
1
A
Air-discharge
Air intake
7
5
6
4
8
Z VIEW
42
74
100
120
173
16
51
35
47
Air-discharge
Air intake
When using a drain pipe, install the drain socket
(field supply) onto the drain port. Seal the other
drain port with the rubber cap.
Air intake
Air intake
(Gas piping connection) While the main gas side pipe is ø25.4,
since connecting the outdoor unit's 3-way valve requires a ø19.05
flare, please be sure to use standard accessories joint piping B or
A for connection (brazing), and connect as follows.
*
1
Specifi cation for pipe connecting indoor unit to outdoor unit.
A
8
E
2
E
P
0
5
2
-
U
Model name
Piping
Connections
12.7
ø
e
d
i
s
d
i
u
q
i
L
25.4
ø
e
d
i
s
s
a
G
(B) Outdoor Unit: U-250PE2E8A
2
3
12
SM830252-01_欧州_Single_8・10HP_TD_SM.indb 16