3-level Teaching
This carries out 3-level teaching (P-1, P-2, P-3) and sets the threshold value
(1_SL) between A and B and the threshold value (2_SL) between B and C as
shown in the diagram below.
After teaching, P-1, P-2 and P-3 are automatically assigned in ascending order to
‘A’, ‘B’, and ‘C’.
Time
Incident light
intensity
9,999
Output
(L-ON)
TEACH : Teaching Mode
Refer to p. 14 ~ for setting procedure
P. 14
1-level Teaching
This sets the shift value to any desired value, and sets the threshold values (1_SL,
2_SL) by means of 1-level teaching.
P. 15
2-level Teaching
This carries out 2-level teaching (P-1, P-2) and sets the threshold values (1_SL,
2_SL).
Time
ON
P-1
1_SL
P-2
2_SL
0
OFF
Time
Shift value
Shift value
ON
1_SL
2_SL
P-1
0
OFF
Incident light
intensity
9,999
Incident light
intensity
9,999
Output
(L-ON)
Output
(L-ON)
Output
(L-ON)
* In this figure, the incident light intensity of
P-1 is less than that of P-2.
P. 13
Full-auto Teaching
This method is used to set the threshold value while the sensing objects are still
moving on the production line, without stopping the production line.
When using window comparator mode
The ‘threshold value’ can be set with any of the 3 teaching methods (‘1-level
teaching’, ‘2-level teaching’ and ‘3-level teaching’). By setting two ‘threshold
values’, both ON and OFF can occur between the two threshold value levels.
Hysteresis
9,999
Incident light
intensity
ON
1_SL
2_SL
OFF
7
Ramco National
(800) 280-6933