4-5. Output Operation Setting Mode
This mode allows the selection of output operation
from either L-ON (Light-ON), or D-ON (Dark-ON).
* Select the output 1 or output 2 beforehand.
ON
OFF
OFF
ON
Threshold
value
Incident light
intensity
Incident light
intensity
Incident light
intensity
Time
Time
Output
operation
Output
operation
Output operation
L-ON
D-ON
L-ON
D-ON
L-ON
(Detection-ON)
D-ON
(Detection-OFF)
Output
operation
L-ON
(Detection-ON)
D-ON
(Detection-OFF)
Normal mode
Output
operation
Hysteresis mode
When setting rising
differential mode
When setting trailing
differential mode
ON
OFF
OFF
OFF
ON
ON
Threshold
value 1
(1_SL)
Threshold
value 2
(2_SL)
Incident
light
intensity
Output
operation
L-ON
D-ON
Window comparator mode
ON level or
OFF level
(2_SL)
OFF level or
ON level
(1_SL)
0
9,999
Press the
MODE key
twice.
Turn the
Jog switch.
Press the
Jog switch.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key
4 times.
The current
setting
9,999
Incident
light
intensity
9,999
1
Press the [MODE key] twice to select the ‘output operation
setting mode’.
2
The current setting for output operation will be displayed.
* The factory setting is ‘L-ON (Light-ON)’.
5
Press the [MODE key] 4 times, the amplifier will return to
‘RUN mode’ (normal sensing operation).
3
If the [Jog switch] is turned, the setting for output operation
(‘
’ side… ‘
’ side… ) will blink on the digital
display.
(
)
4
If the [Jog switch] is pressed, output operation will quickly
blink on the digital display and the selected ‘output operation’
will be confirmed.
The digital display will not blink if the setting has not been
changed.
22