The status condition when sensing object ‘C’ is present
that has the greatest intensity of incident light.
Press the
Jog switch.
Incident light
intensity for P-3.
Upper limit value 2_SL
Lower limit value 1_SL
Upper and lower limits have
not been correctly set.
The symbol ‘
’ will be
displayed repeatedly.
Press the
MODE key 5 times.
7
If the [Jog switch] is pressed while in the status condition
when sensing object ‘C’ is present that has the greatest
intensity of incident light, the display will blink the incident
light intensity reading (red).
8
The display will indicate whether the upper and lower limits
have been correctly set and the setting for ‘lower limit value
1_SL’ (green) will be displayed.
•
If ‘ ’ (red) is blinking…the upper and lower limits have
been set correctly.
•
If ‘ ’ (red) is blinking…the upper and lower limits have
not been set correctly.
9
Then the setting for ‘upper limit value 2_SL’ (green) will be
displayed.
0
By pressing the [MODE key] 5 times, the amplifier will return
to ‘RUN mode’ (normal sensing operation).
‘Lower limit value 1_SL’ (green) and incident light intensity
(red) will be displayed.