6-7. Stored Value Comparison Function
This displays the stored incident light intensity value and the present incident light intensity value at the same
time so that you can check for things such as drops in incident light intensity.
* Before using the stored value comparison function, you need to store the present incident light intensity.
Present value
Stored value
Press the
MODE key 5 times.
Turn the Jog switch twice
toward the ‘
Ⳮ
’ direction.
Turn the Jog switch 5 times
toward the ‘
Ⳮ
’ direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the
MODE key once.
Press the
MODE key once.
Press the
MODE key once.
1
Press the [MODE key] 5 times to select ‘PRO mode’.
3
Press the [Jog switch] to enter the ‘display switching’ state.
4
Turn the [Jog switch] 5 times toward the ‘
Ⳮ
’ direction, to
enter the ‘stored value comparison setting’ state.
5
If the [Jog switch] is pressed twice, the incident light intensity
(green) that was stored by the present value storage function
and the present incident light intensity (red) will be displayed.
6
If the [MODE key] is pressed twice, the amplifier will return to
‘PRO2 mode’.
7
Press the [MODE key] once, the amplifier will return to ‘RUN
mode’ (normal sensing operation).
2
Turn the [Jog switch] twice toward the ‘
Ⳮ
’ direction, to
select ‘PRO2 mode’.
37
Ramco National
(800) 280-6933
www.panasonicsensors.com